Unit of Measure

Specifications

Available

Manufacturer Stock

Brands

Vitec

Manufacturer

Vitec

Type

57P

Frequency Range

50 kHz

Rated Peak Sense Current

20 A

Electrical Characteristics at 25 Degree Celsius (ºC) Temperature

Turns (± 5%)

400

Minimum Inductance (1-3)

300 mH

Inductance Test Typical Voltage

4 V

Direct Current Resistacne (DCR) (1-3)

20 Ω
Terminating Typical Resistance1 400 Ω

Maximum Unipolar Rating

1200 Amp ms

Industry Standards

Restriction of Hazardous Substances (RoHS) Compliant

Features

Features

  • Designed for use with switching power supplies.
  • Low cost epoxy encapsulated construction.
  • Materials meet flammability requirement of UL94V-0.
  • Built to EN 60950:1992 A11:1997.
  • RoHS compliant version available.

Note

Note

Tolerances unless otherwise specified: .XX±.01 [0.X±0.25]
  • 1 For Voltage Across Terminating Resistance of 1 Volt per Ampere.