PUI Audio?'s High-Temp line of products is designed to meet and exceed the needs of the automotive industry with ultra-wide operating temperatures. The SMT-1341-T-HT-R is designed for high output at 2 kHz in a small package.
  • Wide -40 ?C to +105 ?C operating temperature
  • ≥ 85 dB output at 10 cm with 5 Vp-p input
Unit of Measure

Specifications

Available

$0.114

Manufacturer Stock

Brands

PUI Audio™

Manufacturer

PUI Audio�, Inc.

Peak-to-Peak Rated Voltage (Vp-p)

5 V

Peak-to-Peak Operating Voltage Range (Vp-p)

1 to 25 V

Current Draw at Rated Voltage

≤ 5 mA

Capacitance at 100 Hertz (Hz) Frequency

15000 pF

Capacitance Tolerance (±) at 100 Hertz (Hz) Frequency

30 %

Minimum Sound Pressure Level (SPL) at 10 Centimeter (cm)

≥ 85 dBA

Resonant Frequency

4100 Hz

Resonant Frequency Tolerance (±)

500 Hz

Housing Material

Liquid Crystal Polymers (LCP)

Acceptable Soldering Methods

Hand Solder Reflow Solder

Environmental Compliances

Restriction of Hazardous Substances (RoHS)

Storage Temperature

-40 ~ +120 ºC

Operating Temperature

-40 ~ +105 ºC

Size

13.5 mm

Tolerance (±)

0.3 mm

Angle Tolerance (±)

3 º

Weight

0.5 g

Reliability Testing

High Temperature Test

Test part at +120 ºC for 120 hours

Low Temperature Test

Test part at -40 ºC for 120 hours

Humidity Test

40±2 ºC, 90~95% RH, 120 hours

Temperature Cycle Test

Total 5 cycles, 1 cycle consisting of -40±2 ºC, 30 minutes 20±5 ºC 15 minutes 120±2 ºC, 30 minutes 20±5 ºC 15 minutes

Vibration Test

Sweep from 10 to 55 Hz and then 55 to 10 under single amplitude of 1.0 mm in 1 minute. The vibration test shall consist of 2 hours per plane in each three mutually perpendicular planes for a total time of 6 hours.

Shock Test

Sounder shall be measured after being applied shock (980 m/s²) for each three mutually perpendicular directions to each of 3 times by half sine wave.

Drop Test

Dropped naturally from 70 cm height onto the surface of 10 mm thick wooden board. 2 directions-upper and side of the part are to be applied.

Note for Reliability Testing

After being placed for 2 to 4 hours at room temperature, the product shall meet specifications, except the SPL should be in ±10 dB compared with initial one.