Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Diameter |
N/A 15 mm |
Diameter Tolerance (±) |
N/A 0.1 mm |
Angle Tolerance (±) |
N/A 3 º |
Rated Input Power |
N/A 1.2 W |
Maximum Input Power |
N/A 1.8 W |
Impedance |
N/A 8 Ω |
Impedance Tolerance (±) |
N/A 15 % |
Sound Pressure Level (SPL) Output |
N/A 88 dBA |
Sound Pressure Level (SPL) Output Tolerance (±) |
N/A 3 |
Testing Condition for Sound Pressure Level (SPL) Output |
N/A Sound Pressure Level (SPL) at 0.1 W/0.1 M (At 0.8, 1.0, 1.2, 1.5, 2.0 kHz) |
Maximum Distortion |
N/A 10 % |
Resonant Frequency |
N/A 900 Hz |
Resonant Frequency Tolerance (±) |
N/A 20 % |
Frequency Range |
N/A 900 ~ 12000 Hz |
Housing Material |
N/A Acrylonitrile Butadiene Styrene (ABS) |
Cone Material |
N/A Mylar® |
Operating Temperature |
N/A -30 ~ +70 ºC |
Weight |
N/A 1.5 g |
Industry Standards |
N/A Conflict-Free Sourcing Initiative (CFSI) Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) Restriction of Hazardous Substances (RoHS) 2002/95/EC |
High Temperature Test |
N/A 85ºC with random humidity for 96 hours |
Low Temperature Test |
N/A -40ºC with random humidity for 96 hours |
Humidity Test |
N/A 40ºC ±2ºC with 90% to 95% relative humidity for 96 hours |
Temperature Cycle Test |
N/A -20ºC to 55ºC, 5 cycles (refer to Temperature Cycle Test Graph) |
Vibration Test |
N/A 1.5 mm movement modulated at 10-55 Hz for 2 hours |
Drop Test |
N/A 75 cm free fall onto 5 mm thick board, 10 cycles |
Note for Mechanical and Environment Testing |
N/A After tests, speaker shall rest for 1 hours. SPL shall not deviate ±3 dB from pre-test measurement. |