Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Directivity |
N/A Omni-Directional |
Data Format |
N/A 1/2 Cycle PDM |
Sensitivity |
N/A -26 dB |
Sensitivity Tolerance (±) |
N/A 1 dB |
Testing Condition for Sensitivity |
N/A 1 kHz at 50 cm with 94 dB source 0 dB=1 V/Pa |
Direct Current (DC) Rated Voltage |
N/A 1.8 V |
Direct Current (DC) Operating Voltage Range |
N/A 1.6 to 3.6 V |
Current Draw at Full Power Mode |
N/A 800 ~ 1000 µA |
Current Draw at Low Power Mode |
N/A 400 ~ 450 µA |
Signal to Noise Ratio at Full Power Mode |
N/A 58 dB |
Signal to Noise Ratio at Low Power Mode |
N/A 56 dB |
Note for Signal to Noise Ratio |
N/A 1 kHz, 94 dB input, A-Weighted |
Frequency Range (-10 dB) |
N/A 20 ~ 15000 Hz |
Total Typical Harmonic Distortion |
N/A 0.5 % |
Testing Condition for Total Typical Harmonic Distortion |
N/A 94 dB at 50 cm, 1 kHz acoustic source |
Load Capacitance |
N/A 140 pF |
Acceptable Soldering Methods |
N/A Reflow Solder |
Acoustic Overload Point (AOP) at Full Power Mode |
N/A 123 dB |
Acoustic Overload Point (AOP) at Low Power Mode |
N/A 120 dB |
Testing Condition for Acoustic Overload Point (AOP) at Low Power Mode |
N/A 10 % THD at 1 kHz, acoustic source 50cm away from microphone |
Environmental Compliances |
N/A Restriction of Hazardous Substances (RoHS)/Halogen Free |
Power Supply Rejection1 | N/A -80 dB |
Testing Condition for Power Supply Rejection |
N/A 100 mVpp Square Wave at 217 Hz, A-Weighted |
Weight |
N/A < 0.3 g |
Maximum Direct Current (DC) Voltage on Any Pin |
N/A 4 V |
Maximum Sound Pressure Level (SPL) Before Damage (Source 50 cm From Microphone) |
N/A 160 dB |
Maximum Mechanical Shock |
N/A 10000 G |
Maximum Vibration |
N/A Pre-MIL-STD-883 Method 2007, Test Condition B |
Operating Temperature (VDD < 3 VDC) |
N/A -40 ~ +100 ºC |
Operating Temperature (VDD > 3 VDC) |
N/A -40 ~ +70 ºC |
Storage Temperature |
N/A -40 ~ +125 ºC |
Ingress Protection Rating |
N/A Ingress Protection (IP57) |
Moisture Sensitivity Level (MSL)2 | N/A 1 |
Clock Frequency at Sleep Mode |
N/A 0 ~ 320 kHz |
Clock Frequency at Low Power Mode |
N/A 351 ~ 800 kHz |
Clock Frequency at Full Power Mode |
N/A 1.024 ~ 4.096 MHz |
Duty Cycle |
N/A 45 ~ 55 % |
Testing Condition for Duty Cycle |
N/A For fCLK ≤ 2.4 MHz the duty cycle must be in the range of 40 ~ 60% and for fCLK > 2.4 MHz the duty cycle must be 50% |
Tolerance (±) |
N/A 0.5 mm |
Angle Tolerance (±) |
N/A 3 º |
High Logic Input |
N/A 0.65 x VDD ~ VDD + 0.3V |
Low Logic Input |
N/A -0.3 ~ 0.35 x VDD |
High Logic Output |
N/A 0.65 x VDD ~ VDD + 0.3V |
Low Logic Output |
N/A -0.3 ~ 0.35 x VDD |
Simulated Reflow (Without Solder) |
N/A Samples for qualification testing require 3 passes 260±5 ºC reflow solder profiles. 2 hours of setting time is required between each reflow profile test. |
Static Humidity |
N/A Precondition at +25 ºC for 1 hour. Expose to +85 ºC with 85% relative humidity for 1000 hours. Dry at room ambient for 3±1 hour before taking final measurement. |
Temperature Shock |
N/A Each cycle shall consist of 30 minutes at -40 ºC, 30 minutes at +125 ºC with 5 minutes transition time. Test duration is for 30 cycles, starting from cold to hot temperature. |
Electrostatic-Sensitive Device (ESD) Sensitivity |
N/A Perform ESD sensitivity threshold measurements for each contact according to MIL-STD-883G, Method 3015.7 for Human Body Model. Identify the ESD threshold levels indicating passage of 8000V Human Body Model. |
Vibration Test |
N/A Vibrate randomly along three perpendicular directions for 30 minutes in each direction, 4 cycles from 20~2000 Hz with a peak acceleration of 20 Gs. |
Shock Test |
N/A Subject samples to half-sine shock pulses (3000±15% Gs for 0.3ms) in each direction, for a total of 18 shocks. |
Drop Test |
N/A Drop samples from 1.5m height onto a steel surface, total 18 times and inspected for mechanical damage. |
Operation Life |
N/A Subject samples to +125ºC for 168 hours under full maximum rated voltage. |
Waterproof Test |
N/A Place 15 microphones in water at 1m depth for 30 minutes. Remove and dissect 5 pieces to check for water ingress. Test remaining 10 microphones for sensitivity after resting at room temperature for 2 hours. |
Note for Reliability Testing |
N/A Microphone frequency response and sensitivity shall not deviate more than ±3 dB. |