Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Directivity |
N/A Omni-Directional |
Data Format |
N/A I2S 24-bit data size with 18-bit precision, 32-bit word size |
Sensitivity |
N/A -26 dB |
Sensitivity Tolerance (±) |
N/A 1 dB |
Testing Condition for Sensitivity |
N/A 1 kHz at 50 cm with 94 dB source 0 dB=1 V/Pa |
Direct Current (DC) Rated Voltage |
N/A 1.8 V |
Direct Current (DC) Operating Voltage Range |
N/A 1.5 to 3.6 V |
Supply Current at Normal Mode |
N/A 820 ~ 1000 µA |
Supply Current at Sleep Mode (Clock Off) |
N/A 5 µA |
Signal to Noise Ratio |
N/A 64 dB |
Note for Signal to Noise Ratio |
N/A 1 kHz, 94 dB input, A-Weighted |
Frequency Range |
N/A 20 ~ 10000 Hz |
Total Typical Harmonic Distortion |
N/A 1 % |
Testing Condition for Total Typical Harmonic Distortion |
N/A 110 dB at 50 cm, 1 kHz acoustic source |
Startup Time (Sensitivity Reaching 90% of Listed Value From Initial Power-Up) |
N/A 20 ms |
Startup Time (From Sleep Mode) |
N/A 20 ms |
Startup Time (From Normal Mode to Sleep Mode) |
N/A 20 ms |
Input Clock Frequency at Normal Mode |
N/A 2.048 ~ 4.096 MHz |
Input Clock Frequency at Sleep Mode |
N/A 320 kHz |
Clock Jitter (Long Term Root Mean Square (RMS)) |
N/A 500 ps |
Load Capacitance |
N/A 140 pF |
Pass Band (Fs = 48 kHz) |
N/A 18 kHz |
Pass Band Attenuation |
N/A 0.5 dB |
Environmental Compliances |
N/A Restriction of Hazardous Substances (RoHS)/Halogen Free |
Power Supply Rejection1 | N/A -86 dB |
Testing Condition for Power Supply Rejection |
N/A 100 mVpp Square Wave at 217 Hz, A-Weighted |
Operating Temperature |
N/A -40 ~ +100 ºC |
Storage Temperature |
N/A -40 ~ +125 ºC |
Tolerance (±) |
N/A 0.5 mm |
Angle Tolerance (±) |
N/A 3 º |
Simulated Reflow (Without Solder) |
N/A Samples for qualification testing require 3 passes 260 ±5 ºC reflow solder profiles. 2 hours of setting time is required between each reflow profile test. |
Static Humidity |
N/A Precondition at +25 ºC for 1 hour. Expose to +85 ºC with 85% relative humidity for 1000 hours. Dry at room ambient for 3 ±1 hour before taking final measurement. |
Temperature Shock |
N/A Each cycle shall consist of 30 minutes at -40ºC, 30 minutes at +125ºC with 5 minutes transition time. Test duration is for 30 cycles, starting from cold to hot temperature. |
Electrostatic-Sensitive Device (ESD) Sensitivity |
N/A Perform ESD sensitivity threshold measurements for each contact according to MIL-STD-883G, Method 3015.7 for Human Body Model. Identify the ESD threshold levels indicating passage of 8000V Human Body Model. |
Vibration Test |
N/A Vibrate randomly along three perpendicular directions for 30 minutes in each direction, 4 cycles from 20~2000 Hz with a peak acceleration of 20 Gs. |
Shock Test |
N/A Subject samples to half-sine shock pulses (3000±15% Gs for 0.3ms) in each direction, for a total of 18 shocks. |
Drop Test |
N/A Drop samples from 1.5m height onto a steel surface, total 18 times and inspected for mechanical damage. |
Operation Life |
N/A Subject samples to +125ºC for 168 hours under full maximum rated voltage. |
Note for Reliability Testing |
N/A Microphone frequency response and sensitivity shall not deviate more than ±3 dB. |