Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Sensitivity (1 Kilohertz (kHz) Frequency at 50 Centimeter (cm))1 | N/A -38 dB |
Sensitivity Tolerance (±) (1 Kilohertz (kHz) Frequency at 50 Centimeter (cm))2 | N/A 1 dB |
Direct Current (DC) Rated Voltage |
N/A 2 V |
Direct Current (DC) Operating Voltage Range |
N/A 1.5 to 3.6 V |
Output Impedance at 1 Kilohertz (kHz) Frequency |
N/A 300 Ω |
Current Consumption at 2 Volts (V) Direct Current (DC) Voltage |
N/A 90 µA |
Current Consumption at 3.6 Volts (V) Direct Current (DC) Voltage |
N/A 100 µA |
Signal to Noise Ratio3 | N/A 62 dB |
Decreasing Voltage4 | N/A 0.5 dB |
Frequency Range |
N/A 20 to 20000 Hz |
Total Harmonic Distortion5 | N/A 0.5 % |
Acoustic Overload Point (AOP) Sound Pressure Level (SPL)6 | N/A 125 dB |
Directivity |
N/A Omni-Directional |
Environmental Compliances |
N/A Halogen Free Restriction of Hazardous Substances (RoHS) |
Power Supply Rejection7 | N/A -90 dB |
Operating Temperature (VDD < 3 VDC) |
N/A -40 ~ +100 ºC |
Operating Temperature (VDD > 3 VDC) |
N/A -40 ~ +70 ºC |
Storage Temperature |
N/A -40 ~ 125 ºC |
Maximum Direct Current (DC) Voltage on Any Pin |
N/A 4 V |
Maximum Sound Pressure Level |
N/A 160 dB |
Maximum Mechanical Shock |
N/A 10000 G |
Maximum Vibration |
N/A Pre-MIL-STD-883 Method 2007, Test Condition B |
Simulated Reflow (Without Solder) |
N/A Samples for qualification testing require 3 passes 260 ±5 ºC reflow solder profiles. 2 hours of setting time is required between each reflow profile test. |
Static Humidity |
N/A Precondition at +25 ºC for 1 hour. Expose to +85 ºC with 85% relative humidity for 1000 hours. Finally, dry at room ambient for 3 ±1 hour before taking final measurement. |
Temperature Shock |
N/A Each cycle shall consist of 30 minutes at -40 ºC, 30 minutes at +125 ºC with 5 minutes transition time. Test duration is for 30 cycles, starting from cold to hot temperature. |
Electrostatic-Sensitive Device (ESD) Sensitivity |
N/A Perform ESD sensitivity threshold measurements for each contact according to MIL-STD-883G, Method 3015.7 for Human Body Model. Identify the ESD threshold levels indicating passage of 8000V Human Body Model. |
Vibration Test |
N/A Vibrate randomly along three perpendicular directions for 30 minutes in each direction, 4 cycles from 20~2000 Hz with a peak acceleration of 20 Gs. |
Drop Test |
N/A Drop samples from 1.5 m height onto a steel surface, total 18 times and inspected for mechanical damage. |
Shock Test |
N/A Subject samples to half-sine shock pulses (3000 ±15 % Gs for 0.3 ms) in each direction, for a total of 18 shocks. |
Operation Life |
N/A Subject samples to +125 ºC for 168 hours under full maximum rated voltage |