Print Back
This product has recognition under the component program of Underwriters Laboratories, inc.
Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A EDI® MINIBRIDGE®

Manufacturer

N/A Electronic Devices Inc.

Peak Reverse Voltage (PRV) per Leg

N/A 1000 V

Number of Phase

N/A 1

Average Forward Current, IF (Av.) TC= 55 Degree Celsius (ºC) Temperature

N/A 50 A

Maximum Peak Surge Current at IFSM (8.3 Millisecond (ms) Time))

N/A 400 A

Maximum Instantaneous Forward Voltage Drop VF = 1.2 V at IF = Pulse Test Pulse Width 300 Micro Second (µs) Duty Cycle 2 Percent (%)

N/A 35 A

Maximum Direct Reverse Current (IR) at Peak Reverse Voltage (PRV) and 25 Degree Celsius (ºC) Temperature

N/A 10 µA

Maximum Direct Reverse Current (IR) at Peak Reverse Voltage (PRV) and 100 Degree Celsius (ºC) Temperature

N/A 100 µA

Thermal Resistance (Total Bridge Rθj-c)

N/A 1.2 ºC/W

Storage Temperature Range (TSTG)

N/A -55 to +175 ºC

Industry Standards

N/A Recognized Component Mark (RU®)

Note

Note

N/A Maximum lead and terminal temperature for soldering, 3/8 in. from case, 5 seconds at 250 ºC.