PUI Audio?'s Mobile Series line of speakers and receivers is designed for cutting-edge applications such as smart watches. The AS01208MS-SC12-WP-R is designed for submersion in water depths greater than 1 meter for 30 minutes when properly mounted. Front mounted double-sided tape, spring contacts, and a rear shock absorbing pad makes for easy integration.
Unit of Measure
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Tolerance (±) |
N/A 0.5 mm |
Angle Tolerance (±) |
N/A 3 º |
Rated Input Power |
N/A 0.3 W |
Maximum Input Power |
N/A 0.5 W |
Impedance |
N/A 8 Ω |
Impedance Tolerance (±) |
N/A 15 % |
Sensitivity |
N/A 87.5 dB |
Sensitivity Tolerance (±) |
N/A 3 dB |
Testing Condition for Sensitivity |
N/A (Sound Pressure Level (SPL) at 2 kHz) 1.55 V at 10 cm in 2 cc Enclosure |
Resonant Frequency in 2 Cubic Centimeter (cc) Enclosure |
N/A 1300 Hz |
Resonant Frequency Tolerance (±) in 2 Cubic Centimeter (cm³) Enclosure |
N/A 20 % |
Frequency Range |
N/A 800 ~ 20000 Hz |
Testing Condition for Frequency Range |
N/A -10 dB |
Total Harmonic Distortion |
N/A <10 % |
Testing Condition for Total Harmonic Distortion |
N/A 2 kHz, 0.1 W |
Ingress Protection Rating |
N/A Ingress Protection (IPX8) |
Buzz, Rattle, etc. |
N/A Should not be Audible with 1.55 V Sine Wave from 1.25 to 5 kHz |
Polarity |
N/A When Positive Voltage is Applied to the Positive Terminal, the Diaphragm will Move Outward |
Operating Temperature |
N/A -20 ~ +60 ºC |
Storage Temperature |
N/A -30 ~ +70 ºC |
Weight |
N/A 0.8 g |
Environmental Compliances |
N/A Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) Restriction of Hazardous Substances (RoHS) |
Materials
Frame Material |
N/A Polyphthalamide (PPA) |
Magnet Material |
N/A Neodymium (NdFeB) |
Diaphragm Material |
N/A Mylar® |
Mechanical Reliability and Environment Testing
High Temperature Test |
N/A 96 hours at +60ºC ± 3ºC followed by three hours in normal room temperature |
Low Temperature Test |
N/A 96 hours at -20 ºC ± 3 ºC followed by three hours in normal room temperature |
Humidity Test |
N/A 96 hours at +30 ºC ± 3 ºC with relative humidity between 92% and 95% followed by 3 hours in normal room temperature |
Vibration Test |
N/A
10-55 to 10 Hz sine sweep with 1.5 mm amplitude 2 hours in each axis X, Y, and Z. |
Drop Test |
N/A Drop the speakers onto a 40 mm thick board 10 times from a height of 75 cm |
Load Test |
N/A White noise is applied at the speakers rated power for 96 hours at room temperature. |
Note for Reliability Testing |
N/A After each test, the speaker's SPL shall be ±3 dB of the original SPL |