Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A PUI Audio™

Manufacturer

N/A PUI Audio�, Inc.

Directivity

N/A Omni-Directional

Data Format

N/A I2S 24-bit data size with 18-bit precision, 32-bit word size

Sensitivity

N/A -26 dB

Sensitivity Tolerance (±)

N/A 1 dB

Testing Condition for Sensitivity

N/A 1 kHz at 50 cm with 94 dB source 0 dB=1 V/Pa

Direct Current (DC) Rated Voltage

N/A 1.8 V

Direct Current (DC) Operating Voltage Range

N/A 1.5 to 3.6 V

Supply Current at Normal Mode

N/A 820 ~ 1000 µA

Supply Current at Sleep Mode (Clock Off)

N/A 5 µA

Signal to Noise Ratio

N/A 64 dB

Note for Signal to Noise Ratio

N/A 1 kHz, 94 dB input, A-Weighted

Frequency Range

N/A 20 ~ 10000 Hz

Total Typical Harmonic Distortion

N/A 1 %

Testing Condition for Total Typical Harmonic Distortion

N/A 110 dB at 50 cm, 1 kHz acoustic source

Startup Time (Sensitivity Reaching 90% of Listed Value From Initial Power-Up)

N/A 20 ms

Startup Time (From Sleep Mode)

N/A 20 ms

Startup Time (From Normal Mode to Sleep Mode)

N/A 20 ms

Input Clock Frequency at Normal Mode

N/A 2.048 ~ 4.096 MHz

Input Clock Frequency at Sleep Mode

N/A 320 kHz

Clock Jitter (Long Term Root Mean Square (RMS))

N/A 500 ps

Load Capacitance

N/A 140 pF

Pass Band (Fs = 48 kHz)

N/A 18 kHz

Pass Band Attenuation

N/A 0.5 dB

Acceptable Soldering Methods

N/A Reflow Solder

Environmental Compliances

N/A Restriction of Hazardous Substances (RoHS)/Halogen Free
Power Supply Rejection1 N/A -86 dB

Testing Condition for Power Supply Rejection

N/A 100 mVpp Square Wave at 217 Hz, A-Weighted

Weight

N/A < 0.3 g

Operating Temperature

N/A -40 ~ +100 ºC

Storage Temperature

N/A -40 ~ +125 ºC
Moisture Sensitivity Level (MSL)2 N/A 1

Tolerance (±)

N/A 0.5 mm

Angle Tolerance (±)

N/A 3 º

Reliability Testing

Simulated Reflow (Without Solder)

N/A Samples for qualification testing require 3 passes 260±5 ℃ reflow solder profiles. 2 hours of setting time is required between each reflow profile test.

Static Humidity

N/A Precondition at +25℃ for 1 hour. Expose to +85℃ with 85% relative humidity for 1000 hours. Dry at room ambient for 3 ±1 hour before taking final measurement.

Temperature Shock

N/A Each cycle shall consist of 30 minutes at -40℃, 30 minutes at +125℃ with 5 minutes transition time. Test duration is for 30 cycles, starting from cold to hot temperature.

Electrostatic-Sensitive Device (ESD) Sensitivity

N/A Perform ESD sensitivity threshold measurements for each contact according to MIL-STD-883G, Method 3015.7 for Human Body Model. Identify the ESD threshold levels indicating passage of 8000V Human Body Model.

Vibration Test

N/A Vibrate randomly along three perpendicular directions for 30 minutes in each direction, 4 cycles from 20~2000 Hz with a peak acceleration of 20 Gs.

Shock Test

N/A Subject samples to half-sine shock pulses (3000±15% Gs for 0.3ms) in each direction, for a total of 18 shocks.

Drop Test

N/A Drop samples from 1.5m height onto a steel surface, total 18 times and inspected for mechanical damage.

Operation Life

N/A Subject samples to +125℃ for 168 hours under full maximum rated voltage.

Note for Reliability Testing

N/A Microphone frequency response and sensitivity shall not deviate more than ±3 dB.

Note

Note

N/A Specifications subject to change or withdrawal without notice.
  • 1 To Full Scale
  • 2 MSL level dependent on product remaining in sealed packaging until use.