The eight ohm, 53 mm square frame AS05308AS-R features a rubber surround, for water and dust resistance, and a vented voice coil former for improved voice coil cooling.
Unit of Measure
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Square Frame Size |
N/A 53 mm |
Voice Coil Diameter |
N/A 1 in |
Rated Input Power |
N/A 10 W |
Maximum Input Power |
N/A 20 W |
Impedance |
N/A 8 Ω |
Impedance Tolerance (±) |
N/A 15 % |
Sensitivity |
N/A 78 dB |
Sensitivity Tolerance (±) |
N/A 3 dB |
Testing Condition for Sensitivity |
N/A (Sound Pressure Level (SPL) at 1 W/1 m) Avg. at 2, 4, 8, and 16 kHz |
Resonant Frequency (Free Air) |
N/A 230 Hz |
Resonant Frequency (Free Air) Tolerance (±) |
N/A 20 % |
Frequency Range |
N/A 100 ~ 40000 Hz |
Frame Material |
N/A Stamped Steel |
Magnet Material |
N/A Neodymium (NdFeB) |
Buzz, Rattle, etc. |
N/A Should not be Audible with 8.95 V Sine Wave from 200 Hz to 20 kHz |
Polarity |
N/A When Positive Voltage is Applied to the Positive Terminal, the Diaphragm will Move Outward |
Operating Temperature |
N/A -20 ~ +60 ºC |
Storage Temperature |
N/A -20 ~ +60 ºC |
Weight |
N/A 120 g |
Industry Standards |
N/A Restriction of Hazardous Substances (RoHS) 2011/65/EU |
Mechanical Reliability and Environment Testing
High Temperature Test |
N/A 96 hours at +60 ºC ± 3 ºC followed by three hours in normal room temperature |
Low Temperature Test |
N/A 96 hours at -20 ºC ± 3 ºC followed by three hours in normal room temperature |
Humidity Test |
N/A 96 hours at +40 ºC ± 3 ºC with relative humidity at 90% ~ 95% followed by 6 hours in normal room temperature |
Temperature Cycle Test |
N/A
The part shall be subjected to 12 cycles using the following procedure: Low temperature: -20 ºC±3 ºC High temperature:+60 ºC±3 ºC Cycle: 2 hours at High, 5 minutes High to Low, 2 hours at Low, 5 minutes Low to High |
Vibration Test |
N/A
10-55 to 10 Hz sine sweep, per minute at 1.5 mm amplitude 2 hours in each axis X, Y, and Z. |
Load Test |
N/A White noise is applied at the speakers rated power for 96 hours at room temperature |
Note for Reliability Testing |
N/A After each test, the speaker's SPL shall be ±3 dB of the original SPL |