PUI Audio?'s eXtreme Series speakers are purpose-built for superior performance. When combined with the APR050SO-R passive radiator, a speaker's low frequency performance can be extended almost a full octave lower, for exceptional bass response without adding space for a tuned vent.
Unit of Measure
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Resonant Frequency |
N/A 78 Hz |
Resonant Frequency Tolerance (±) |
N/A 10 % |
Mechanical Q-Factor (Qms) |
N/A 2.53 |
Moving Mass |
N/A 4.06 g |
Mechanical Compliance |
N/A 0.928 mm/N |
Mechanical Stiffness |
N/A 1.09 N/mm |
Mechanical Resistance |
N/A 0.81 kg/s |
Diaphragm Surface Area |
N/A 8.7 cm² |
Frame Material |
N/A Stamped Steel |
Diaphragm Material |
N/A Stamped Steel |
Surround Material |
N/A Thermoplastic Elastomers (TPE) |
Weight |
N/A 5.67 g |
Ingress Protection Rating |
N/A Ingress Protection (IP65) |
Environmental Compliances |
N/A Registration, Evaluation, Authorization and Restriction of Chemicals (REACH 197) Restriction of Hazardous Substances (RoHS) 2015/863/EU |
Operating Temperature |
N/A -20 ~ +60 ºC |
Tolerance (±) |
N/A 0.5 mm |
Angle Tolerance (±) |
N/A 3 º |
Mechanical and Environment Testing
High Temperature Test |
N/A 96 hours at +60 ºC ± 2 ºC followed by 0.5 hours in normal room temperature |
Low Temperature Test |
N/A 96 hours at -20 ºC ± 3 ºC followed by 0.5 hours in normal room temperature |
Humidity Test |
N/A 96 hours at +40 ºC ± 2 ºC with relative humidity at 80% followed by 12 hours in normal room temperature |