PUI Audio??s all-new API-4260-LW150-2-R audio programmable indicator makes adding audio files easier than ever before! Connect the API-4260-LW150-2-R to any computer (Window, Linux, or Mac) and simply drag-and-drop mono audio files the same as you would a USB flash drive.
A larger 4MB storage size allows for longer files (WAV or MP3) or for sequential playback of multiple files, while the all-new internal DAC allows for 48 kHz sampling rates for true frequency response out to 20 kHz.
A larger 4MB storage size allows for longer files (WAV or MP3) or for sequential playback of multiple files, while the all-new internal DAC allows for 48 kHz sampling rates for true frequency response out to 20 kHz.
Unit of Measure
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Direct Current (DC) Rated Voltage |
N/A 12 V |
Direct Current (DC) Operating Voltage Range |
N/A 7 ~ 24 V |
Current Draw at Rated Voltage |
N/A 350 mA |
Minimum Sound Pressure Level (SPL) at 10 Centimeter (cm) |
N/A 100 dBA |
Frequency Range |
N/A 100 ~ 20000 Hz |
Tone |
N/A Repeating |
Housing Material |
N/A Acrylonitrile Butadiene Styrene (ABS) |
Terminal Material |
N/A Lead Wires UL1430 AWG 26 |
Weight |
N/A 27 g |
Acceptable Soldering Methods |
N/A Hand Solder |
Compliance |
N/A
Restriction of Hazardous Substances (RoHS)/Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) Federal Communications Commission (FCC) Part 15 Class B European Conformity (CE) EN61000-6-1 European Conformity (CE) EN61000-6-3 |
Storage Temperature |
N/A -30 ~ +70 ºC |
Operating Temperature |
N/A -20 ~ +60 ºC |
Tolerance (±) |
N/A 0.5 mm |
Angle Tolerance (±) |
N/A 3 º |
Mechanical and Environment Testing
High Temperature Test |
N/A 96 hours at 60 °C followed by 6 hours in normal room temperature |
Low Temperature Test |
N/A 96 hours at -20 °C followed by 6 hours in normal room temperature |
Humidity Test |
N/A 96 hours at +40 ºC with relative humidity at 92 % followed by 3 hours in normal room temperature |
Temperature Cycle Test |
N/A Part is testing according to the below chart for 5 cycles |
Vibration Test |
N/A 1.5 Hz to 5 Hz to 1.5 Hz cycles, 15 minutes per cycle. 2 hours in each axis X, Y, and Z. |
Drop Test |
N/A Drop product onto 40 mm thick wooden board 10 times from a height of 75 cm. |