Unit of Measure
Specifications
|
Life Expectance L10 (At Label Voltage)
|
Mechanical Specifications
|
Environmental
|
Note
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI |
Manufacturer |
N/A Sanyo Denki Co., Ltd. |
Direct Current (DC) Rated Voltage |
N/A 12 V |
Operating Direct Current (DC) Voltage |
N/A 7 to 13.2 V |
Lead Wire |
N/A Black (-) Sensor Red Wire (+) Yellow |
Size |
N/A 38 x 38 x 28 mm |
Non Condensing Storage Temperature |
N/A -20 to 70 ºC |
Mass |
N/A 50 g |
Sound Pressure Level (SPL) at 100 Percent (%) Duty Cycle |
N/A 50 dBA |
Expected Life |
N/A L10: Survival Rate: 90 % at 60 ºC, Rated Voltage, and continuously run in a free air state. |
Rated Current |
N/A 0.4 A |
Rated Input Power |
N/A 4.8 W |
Rated Speed |
N/A 13500 min-1 |
Maximum Air Flow |
N/A 0.48 m³/min17 ft³ |
Maximum Static Pressure |
N/A 220 Pa0.924 inH2O |
Life Expectance L10 (At Label Voltage)
Continuous Operation Time |
N/A 40000 hours |
Continuous Operation Temperature |
N/A 60 ºC |
Mechanical Specifications
Frame Material |
N/A Plastic |
Impeller Material |
N/A Plastic |
Industry Standards |
N/A Canadian Standards Association (CSA®) Flammability: Underwriters Laboratories (UL) 94V-0 (For Frame) Flammability: Underwriters Laboratories (UL) 94V-1 (For Impeller) Recognized Component Mark (RU®) Technical Inspection Association (TUV) |