Scope:
This Specification defines the electrical and mechanical characteristics of the DC brushless axial flow fan. The fan motor is with single phase and four poles.
This Specification defines the electrical and mechanical characteristics of the DC brushless axial flow fan. The fan motor is with single phase and four poles.
Unit of Measure
Specifications
|
Characters
|
Mechanical
|
Environmental
|
Protection
|
Basic Reliability Requirement
|
Lead Wire
|
Note
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A Delta |
Manufacturer |
N/A Delta |
Re Ozone Depleting Substances |
N/A No containing PBBs, PBBOs, CFCs, PBBEs, PBDPEs, and HCFCs. |
Production Location |
N/A Products will be produced in China or Taiwan. |
Characters
Direct Current (DC) Rated Voltage |
N/A 12 V |
Direct Current (DC) Operating Voltage Range |
N/A 10.8 to 12.6 V |
Input Current |
N/A 1.30 A |
Maximum Input Current |
N/A 1.82 A |
Input Power |
N/A 15.60 W |
Maximum Input Power |
N/A 21.84 W |
Speed (Front) |
N/A 16000 rpm |
Reference Speed (Rear) |
N/A 15400 rpm |
Maximum Air Flow at Zero Static Pressure |
N/A 0.911 m³/min32.179 ft³/min |
Minimum Air Flow at Zero Static Pressure |
N/A 0.820 m³/min28.961 ft³/min |
Maximum Air Pressure at Zero Air Flow |
N/A 66.824 mmH2O2.631 inH2O |
Minimum Air Pressure at Zero Air Flow |
N/A 54.127 mmH2O2.131 inH2O |
Average Acoustical Noise |
N/A 64.5 dBA |
Maximum Average Acoustical Noise |
N/A 68.5 dBA |
Insulation Type |
N/A Underwriters Laboratories (UL): Class A |
Minimum Insulation Strength at 500 Volt (V) Direct Current (DC) Voltage |
N/A 10 MΩ |
Minimum Dielectric Strength at 500 Volts (V) Alternating Current (AC) Voltage, 50/60 Hertz (Hz), 1 Minute |
N/A 5 mA |
External Cover |
N/A Open Type |
Note for Life Expectancy |
N/A 70000 hours |
Rotation |
N/A Two fans rotate in counter directions showed in the name plate side |
Over Current Shut Down |
N/A The current will shut down when locking rotor. |
Mechanical
Frame Material |
N/A Plastic UL: 94V-0 |
Impeller Material |
N/A Plastic UL: 94V-0 |
Bearing System |
N/A 2 Ball Bearings |
Weight |
N/A 83 g |
Environmental
Operating Temperature |
N/A -10 to +60 ºC |
Storage Temperature |
N/A -40 to +75 ºC |
Operating Relative Humidity (RH) |
N/A 5 to 90 % |
Storage Relative Humidity (RH) |
N/A 5 to 95 % |
Protection
Locked Rotor Protection |
N/A Impedance of motor winding protects motor from fire in 96 hours of locked rotor condition at the rated voltage. |
Polarity Protection |
N/A Be capable of withstanding if reverse connection for positive and negative leads. |
Basic Reliability Requirement
Thermal Cycling |
N/A
Low Temperature: -40 ºC High Temperature: +80 ºC Soak Time: 30 Minutes Transition Time < 5 Minutes Duty Cycles: 5 |
Humidity Exposure |
N/A
Temperature: +25 ºC ~ +65 ºC Humidity: 90-98% RH at +65 ºC for 4 hours/cycle Power: Non-operating Test Time: 168 hours |
Vibration |
N/A
Temperature: +25 ºC Orientation: X, Y, Z Power: Non-operating Vibration Level: Overall gRMS = 3.2 Test Time: 2 hours on each orientation |
Mechanical Shock |
N/A
Temperature: +25 ºC Orientation: X, Y, Z Power: Non-operating Acceleration: 20 G min. Pulse: 11 ms half-sine wave Number of shocks: 5 shocks for each direction |
Life |
N/A
Temperature: Max, Operating Temperature Power: Operating Duration: 1000 hours min. |
Lead Wire
Lead Wire |
N/A
UL 1061-F - AWG #28 Red Wire Positive (+) Black Wire Negative (-) Front Fan Black Wire Negative (-) Red Wire Positive (+) White Wire Frequency (F00) Green Wire Speed Control (PWM) Rear Fan Brown Wire Negative (-) Orange Wire Positive (+) Blue Wire frequency (F00) Yellow Wire Speed Control (PWM) |
Note
Note |
N/A
|
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok