The model have ribs and pulse sensors.
Unit of Measure

Specifications

Available

Manufacturer Stock

Brands

Sanyo Denki

Manufacturer

Sanyo Denki Co., Ltd.

Rated Voltage

12 V

Operating Voltage Range

7 to 13.8 V

Rated Current

0.195 A

Rated Input Power

2.34 W

Rated Speed

8700 rpm

Maximum Air Flow

0.32 m³/min11.3 ft³/min

Maximum Static Pressure

102.9 Pa0.414 inH2O
Sound Pressure Level (SPL)1 37 dBA

Operating Temperature

-20 to +70 ºC
Expected Life at 60 Degree Celsius (ºC) Temperature2 60000 hours
Expected Life at 40 Degree Celsius (ºC) Temperature3 90000 hours

Frame Material

Plastic UL 94V-0

Impeller Material

Plastic UL 94V-1

Motor Protection Function

Locked Rotor Burnout Protection Reverse Polarity Protection
Dielectric Strength4 50/60 Hz, 500 VAC, for 1 minute
Minimum Insulation Resistance at 500 Volt (V) Direct Current (DC) Voltage5 10 MΩ
Storage Temperature6 -30 to +70 ºC

Lead Wire

Negative: Black or Blue Positive: Red Sensor: Yellow

Size

40 x 40 x 28 mm

Mass

52 g

Industry Standards

Canadian Standards Association (CSA®) Recognized Component Mark (RU®) TÜV Rheinland Certified

Note

Note

  1. Sensor and control options are available for selection.
  2. Short Lead Time Service applicable models.
  • 1 A-weighted sound pressure level (SPL) at 1 m away from the air inlet.
  • 2 L10 life: 90% survival rate for continuous operation in free air at 60 ºC, rated voltage.
  • 3 Expected life at 40 ºC is for reference only.
  • 4 Between lead wire conductors and frame
  • 5 Between lead wire conductors and frame
  • 6 Non-condensing