Print Back
Accepts wire sizes up to 0.028" dia.
Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A Mill-Max®

Manufacturer

N/A Mill-Max�

Mounting Feature

N/A Press-Fit into a Non-Plated Through Hole (NPTH)
Mounting Hole Diameter1 N/A 0.057 in1.448 mm

Pin Diameter Range

N/A 0.015 to 0.025 in0.381 to 0.635 mm

Packaging

N/A Packaged in Bulk
Restriction of Hazardous Substances (RoHS)2 N/A true
Product Lifecycle3 N/A Active

Materials

Shell Material4 N/A Brass Alloy
Shell Plating5 N/A 10 µin Gold over Nickel
Contact Plating6 N/A 30 μin Gold over Nickel

Technical Specifications

Minimum Durability7 N/A 1000 cycles
Operating Temperature Range8 N/A -55/+125 ºC
Current Rating at 10 Degree Celsius (ºC) Temperature Rise9 N/A 3 A
Maximum Contact Resistance10 N/A 10 mΩ
Shock11 N/A No Elect. Discontinuity > 1 μs at 50 g
Vibration12 N/A No Elect. Discontinuity > 1 µs at 10 to 2000 Hz, 20 G

Standard Tolerances

Standard Length Tolerance (±)

N/A 0.005 in0.13 mm

Standard Diameter Tolerance (±)

N/A 0.002 in0.051 mm

Standard Angle Tolerance (±)

N/A 2 º

Additional Notes and Specifications

Additional Notes and Specifications

N/A In the interest of improved design, quality and performance, Mill-Max® reserves the right to make changes in its specifications without prior notice. Specifications and tolerances are provided wherever possible. The tolerance on dimensions of critical to function features is typically held tighter than the stated standard tolerances, such as press-fits, holes and lengths affecting the coplanarity of SMT products. Due to the wide variety of interconnects Mill-Max® offers, the specific tolerances vary from product to product. If you need information regarding the tolerance of a particular part, please contact Technical Services.
  • 1 This is a general guideline; your application may require different specifications
  • 2 Mill-Max® products labeled with the RoHS symbol are compliant with all three RoHS Directives. All of our products previously described as RoHS (2002/95/EC) and RoHS-2 (2011/65/EC) are also compliant with RoHS-3 (2015/863/EU).
  • 3 Part is Active and in Production, No Scheduled Obsolescence
  • 4 Brass Alloy 360 per ASTM B 16, or 385 per ASTM B455
  • 5 GOLD per ASTM B 488, Type 1 (99.7% min. gold), Code C (130-200 HK {Knoop hardness}); NICKEL per ASTM B 689, Type 2 (Bright)
  • 6 GOLD per ASTM B 488, Type 1 (99.7% min. gold), Code C (130-200 HK {Knoop hardness}), NICKEL per ASTM B 689, Type 2 (Bright)
  • 7 Receptacles are capable of 1000 Minimum insertion/extraction cycles for a broad range of applications. Mating pin size, shape and finish, along with application specific variables, will affect the life of a receptacle contact.
  • 8 Per IEC 60512-11-(4,-9,-10,-12)
  • 9 Per IEC 60512-5-1, Current Carrying Capacity (evaluated at 10ºC Temp. Rise)
  • 10 Per EIA-364-23C, Low Level Contact Resistance
  • 11 Per IEC 60512-6-3: Test 6c: Shock
  • 12 Per IEC 60512-6-4: Test 6d: Vibration (sinusoidal)