Print Back
5 x 20 mm Time-lag fuse, high surge-proof, enhanced breaking capacity, glass tube body cartridge fuse designed, approved and complied with IEC 60127-2,standard sheet 6.
Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A Bel Fuse Inc.

Manufacturer

N/A Bel Fuse Inc.

Industry Standards

N/A Canadian Standards Association (CSA®) Canadian UL Recognized United States (cURus) China Compulsory Certification (CCC) European Conformity (CE) Marked

Physical Specifications

Body Material

N/A Glass

Cap Material

N/A Nickel Plated Brass Caps

Lead Material

N/A Matte Tin Plated Copper

Marking on Fuse

N/A 250V Appropriate Safety Logos bel Current Rating E Restriction of Hazardous Substances (RoHS) Compliant T

Marking on Label

N/A 5ET 5ETP Appropriate Safety Logos bel China Restriction of Hazardous Substances (RoHS) Compliant Current Rating E Interrupting Rating T Voltage Rating

Electrical Specifications

Ampere Rating

N/A 2 A

Typical Cold Resistance

N/A 0.039 Ω

Maximum Volt-drop at 100 Percent (%)

N/A 0.12 V

Melting I2T < 10 Meter Seconds (ms)

N/A 92 A2 s

Melting I2T at 10 Inch (in)

N/A 95 A2 s

Maximum Power Dissipation

N/A 0.61 W

Environmental Specifications

Shock Resistance

N/A MIL-STD-202G, Method 213B, Test Condition 1 (100 G's peak for 6 milliseconds; Sawtooth waveform)

Vibration Resistance

N/A MIL-STD-202G, Method 201A (10-55 Hz, 0.06 inch, total excursion)

Salt Spray Resistance

N/A MIL-STD-202G, Method 101E, Test Condition B (48 hrs)

Insulation Resistance

N/A MIL-STD-202G, Method 302, Test Condition B (After Opening) 100,000 ohm minimum

Solderability Test

N/A MIL-STD-202G, Method 208H

Resistance to Solder Heat

N/A MIL-STD-202G, Method 210F, Test Condition B. (260 +/-5 ºC,10 +/-1 sec)

Thermal Shock

N/A MIL-STD-202G, Method 107G, Test Condition B (-65 ºC to +125 ºC)

Operating Temperature

N/A -55 to 125 ºC

Terminal Strength

N/A IEC-68-2-21

Features

Features

N/A
  • Meet IEC standard 60127-2, sheet 6
  • Wide operating temperature range
  • Bulk and Tape & Reel packing available
  • Full compliance with EU Directive 2011/65/EU and amending directive 2015/863
  • Halogen Free
  • Lead-Free

Applications

Applications

N/A Provide individual protection for components or internal circuits.
  • Power supplies
  • Battery charger
  • Monitor
  • Adapter

Note

Note

N/A Specifications subject to change without notice.