Print Back
Unit of Measure

Specifications

Available

Manufacturer Stock

Brands

American Zettler®

Manufacturer

American Zettler�

Contacts

Arrangement

Single Pole Double Throw (SPDT) (1 Form C) Single Pole Single Throw (SPST) (1 Form A)

Maximum Switched Power Resistive Load Rating

210 W2770 V·A

Maximum Switched Current Resistive Load Rating (1 Form A)

15 A

Maximum Switched Current Resistive Load Rating (1 Form C)

10 A

Maximum Switched Direct Current (DC) Voltage Resistive Load Rating

30 V

Maximum Switched Alternating Current (AC) Voltage Resistive Load Rating

277 V

Rated Load Current (Underwriter Laboratories (UL))

1 Form A
15 A at 125 VAC, General use, 6 k cycles, 70ºC
12 A at 125 VAC, General use, 100 K cycles, 85ºC
10 A at 277 VAC, General use, 100 k cycles 70ºC
10 A at 277 VAC, General use, 20 k cycles 85ºC
12 A at 120 VAC, Res. 6 k cycles 70ºC
TV-5 120 VAC 70ºC
500 W, 120 VAC Tungsten 70ºC
9.8 FLA 1/2 HP at 125 VAC, 6 k Cycles 70ºC
125 VA at 120 VAC Pilot Duty, 100 k cycles, 70ºC
10 A at 28 VDC, Res. 100 K cycles 70ºC
1 Form C
10 A at 120 VAC, Res, 100 k cycles, (N.O.) 70ºC
10 A at 120 VAC, Res, 6 k cycles, (N.C.) 70ºC
10 A at 277 VAC, General Use, 100 k cycles, (N.O./N.C.) 70ºC
10 A at 277 VAC, General use, 20 k cycles (N.O./N.C.) 85ºC
9.8 FLA, 58.8 LRA 1/2 HP at 125 VAC,6 K cycles (N.O.) 70ºC
10 A at 28 VDC, Res. 100 k cycles (N.O.) 70ºC
1 Form A

Rated Load Current (Technischer Überwachungsverein (TÜV))

10 A at 277 VAC, Resistive, 25 k cycles, 85ºC
1 Form C
5 A at 250 VAC, Resistive, 25 k cycles, 85ºC
10 A at 277 VAC, Resistive, 10 k cycles, 85ºC
12 A at 125 VAC, Resistive, 10 k cycles, 85ºC

Rated Load Current (Verband Deutscher Elektrotechniker (VDE))

10 A at 250 VAC, resistive, 70ºC, 50k cycles (N.O.)
12 A at 125 VAC, resistive, 25ºC, 50k cycles (N.O.)
1 Form C only
5 A at 250 VAC, res., 70ºC, 50k cycles, (N.C.)

Material

Silver Tin Oxide, (Gold Plating Available)
Initially Resistance1 < 100 mΩ

General Data

Mechanical Life Expectancy (Minimum Operations)

1 x 107

Electrical Life Expectancy (Minimum Operations)

1 x 105 at 10 Ampere (A) and 277 Alternating Current (AC) Voltage Respectively

Maximum Operate Time

10 ms

Release Time (Typical)

5 Millisecond (ms) Maximum (with no Coil Suppression)

Dielectric Strength at Sea Level for 1 Minute (min)

1500 Root Mean Square (RMS) Voltage (VRMS) contact to Coil 750 Root Mean Square (RMS) Voltage (VRMS) Across Contacts

Insulation Resistance

100 Megaohm (MΩ) Minute (min) at 500 Direct Current (DC) Voltage 50 Percent (%) RH

Dropout

Greater than 10 Percent (%) of Nominal Coil Voltage

Operating Ambient Temperature at Nominal Coil Voltage (Class B)

-40 to 90 ºC-40 to 194 ºF

Operating Ambient Temperature at Nominal Coil Voltage (Class F)

-40 to 110 ºC-40 to 230 ºF

Storage Ambient Temperature at Nominal Coil Voltage

-40 to 130 ºC-40 to 266 ºF

Vibration at 10 to 55 Hertz (Hz)

0.062 in. DA

Shock

10 g

Enclosure

Polybutylene Terephthalate (PBT) Polyester

Terminals

Tinned Copper Alloy Polycarbonate (PC)

Maximum Solder Temperature

270 ºC518 ºF

Maximum Solder Time

5 seconds

Maximum Solvent Temperature

80 ºC176 ºF

Maximum Immersion Time

30 seconds

Approximate Weight

10 g

Coil Specification

Power at Pickup Voltage

203 mW

Maximum Continuous Power Dissipation (Class B)

1.8 W

Maximum Continuous Power Dissipation (Class F)

2.4 W

Temperature Rise

32 ºC58 ºF

Maximum Power Temperature (Class B)

130 ºC266 ºF

Maximum Power Temperature (Class F)

155 ºC311 ºF

Nominal Coil Direct Current (DC) Voltage

48 V

Must Operate Direct Current (DC) Voltage

36 V

Maximum Continuous Direct Current (DC) Voltage

62.4 V

Coil Resistance (±) 10 Percent (%)

6400

Coil Resistance Tolerance (±) 10 Percent (%)

15

Features

Features

  • High performance
  • Low seated height
  • Flux tight and sealed versions available
  • Class B insulation (130ºC) standard
  • Class F insulation (155ºC) available
  • UL, CUR file E44211
  • TÜV file R50161256
  • VDE certificate 40047375

Note

Note

  • All values at 20ºC (68ºF).
  • Relay may pull in with less than “Must Operate” value.
  • Unsealed relays should not be dip cleaned.
  • Specifications subject to change without notice.
  • 1 6 V, 1 A method