Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A PUI Audio™

Manufacturer

N/A PUI Audio�, Inc.

Rated Voltage (V0-p)

N/A 3 V

Operating Voltage Range (V0-p)

N/A 2 ~ 5 V
Current Draw at Rated Voltage1 N/A ≤ 100 mA

Coil Resistance

N/A 12 Ω

Coil Resistance Tolerance (±)

N/A 2 Ω

Minimum Sound Pressure Level (SPL) at 10 Centimeter (cm)

N/A ≥ 80 dBA

Resonant Frequency

N/A 4000 Hz

Resonant Frequency Tolerance (±)

N/A 500 Hz

Acceptable Soldering Methods

N/A Hand Solder Reflow Solder

Environmental Compliances

N/A Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) Restriction of Hazardous Substances (RoHS)

Operating Temperature

N/A -40 ~ +105 ºC

Storage Temperature

N/A -40 ~ +120 ºC

Housing Material

N/A Liquid Crystal Polymers (LCP)

Terminal Material

N/A Tin Plated Brass

Weight

N/A 0.12 g

Reliability Testing

High Temperature Test

N/A The part shall be capable of withstanding a storage temperature is +120℃ for 120 hours

Low Temperature Test

N/A The part shall be capable of withstanding a storage temperature is -40℃ for 120 hours

Humidity Test

N/A 40±2 ºC, 90 ~ 95% RH, 120 hours

Temperature Cycle Test

N/A Total 5 cycles,
1 cycle consisting of -40±2 ºC, 30 minutes
20±5 ºC 15 minutes
120±2 ºC, 30 minutes
20±5 ºC 15 minutes

Vibration Test

N/A The part shall be subjected to a vibration cycle that is 10 Hz in a period of 1 minute. Total peak amplitude shall be 1.52 mm (9.3 g).

The vibration test shall consist of 2 hours per plane in each three mutually perpendicular planes for a total time of 6 hours.

Drop Test

N/A Mount part to 170 g fixture and drop from a height of 150 cm onto cement floor for 10 cycles

Terminal Lead Pull Test

N/A The part shall be pulled with a force of 9.8 N for 10±1 second, axially, and shall not shows signs of damage.

Note for Reliability Testing

N/A After each test, part shall meet specifications with an SPL variance of no more than ±10 dB.

Note

Note

N/A Specifications or changes may not be made without prior customer notification and approval.
  • 1 At rated voltage with 50% duty cycle 4 kHz positive biased square-wave.