The model have pulse sensors.

Unit of Measure

Specifications

Available

Manufacturer Stock

Brands

Sanyo Denki

Manufacturer

Sanyo Denki Co., Ltd.

Rated Voltage

24 V

Operating Voltage Range

12 to 27.6 V

Rated Current

0.07 A

Rated Input Power

1.68 W

Rated Speed

6200 rpm

Maximum Air Flow

0.125 m³/min4.4 ft³/min

Maximum Static Pressure

215 Pa0.86 inH2O
Sound Pressure Level (SPL)1 43 dBA

Operating Temperature

-20 to +70 ºC
Expected Life at 60 Degree Celsius (ºC) Temperature2 40000 hours
Expected Life at 40 Degree Celsius (ºC) Temperature3 70000 hours

Frame Material

Plastic

Impeller Material

Plastic

Flammability

Underwriters Laboratories (UL) 94V-0

Motor Protection Function

Locked Rotor Burnout Protection Reverse Polarity Protection
Dielectric Strength4 50/60 Hz, 500 VAC, for 1 minute
Minimum Insulation Resistance at 500 Volt (V) Direct Current (DC) Voltage5 10 MΩ

Storage Temperature

-30 to +70 ºC

Lead Wire

Negative: Black

Positive: Red

Sensor: Yellow

Size

52 x 15 mm

Mass

33 g

Industry Standards

Canadian UL Recognized United States (cURus) TÜV Rheinland Certified

Note

Note

  1. Sensor and control options are available for selection.
  2. Short Lead Time Service applicable models.
  • 1 A-weighted sound pressure level (SPL) at 1 m away from the air inlet.
  • 2 L10 life: 90% survival rate for continuous operation in free air at 60 ºC, rated voltage.
  • 3 Expected life at 40 ºC is for reference only.
  • 4 Between lead wire conductors and frame
  • 5 Non-condensing