Unit of Measure
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Sensitivity (1 Kilohertz (kHz) Frequency at 50 Centimeter (cm))1 | N/A -42 dB |
Sensitivity Tolerance (±) (1 Kilohertz (kHz) Frequency at 50 Centimeter (cm))2 | N/A 1 dB |
Direct Current (DC) Rated Voltage |
N/A 1.5 V |
Direct Current (DC) Operating Voltage Range |
N/A 1.5 to 3.6 V |
Output Impedance at 1 Kilohertz (kHz) Frequency |
N/A 300 Ω |
Current Consumption at 2 Volts (V) Direct Current (DC) Voltage |
N/A 90 µA |
Current Consumption at 3.6 Volts (V) Direct Current (DC) Voltage |
N/A 200 µA |
Signal to Noise Ratio3 | N/A 58 dB |
Decreasing Voltage4 | N/A 0.5 dB |
Frequency Range |
N/A 20 to 20000 Hz |
Total Harmonic Distortion5 | N/A 0.5 % |
Acoustic Overload Point (AOP) Sound Pressure Level (SPL)6 | N/A 125 dB |
Directivity |
N/A Omni-Directional |
Acceptable Soldering Methods |
N/A Reflow Solder |
Environmental Compliances |
N/A Halogen Free Restriction of Hazardous Substances (RoHS) |
Power Supply Rejection7 | N/A -90 dB |
Weight |
N/A < 0.3 g |
Operating Temperature (VDD < 3 VDC) |
N/A -40 ~ +100 ºC |
Operating Temperature (VDD > 3 VDC) |
N/A -40 ~ +70 ºC |
Storage Temperature |
N/A -40 ~ 125 ºC |
Moisture Sensitivity Level (MSL)8 | N/A 1 |
Absolute Maximum Ratings
Maximum Direct Current (DC) Voltage on Any Pin |
N/A 4 V |
Maximum Sound Pressure Level |
N/A 160 dB |
Maximum Mechanical Shock |
N/A 10000 G |
Maximum Vibration |
N/A Pre-MIL-STD-883 Method 2007, Test Condition B |
Reliability Testing
Simulated Reflow (Without Solder) |
N/A Samples for qualification testing require 3 passes 260 ±5 ºC reflow solder profiles. 2 hours of setting time is required between each reflow profile test. |
Static Humidity |
N/A Precondition at +25 ºC for 1 hour. Expose to +85 ºC with 85% relative humidity for 1000 hours. Finally, dry at room ambient for 3 ±1 hour before taking final measurement. |
Temperature Shock |
N/A Each cycle shall consist of 30 minutes at -40 ºC, 30 minutes at +125 ºC with 5 minutes transition time. Test duration is for 30 cycles, starting from cold to hot temperature. |
Electrostatic-Sensitive Device (ESD) Sensitivity |
N/A Perform ESD sensitivity threshold measurements for each contact according to MIL-STD-883G, Method 3015.7 for Human Body Model. Identify the ESD threshold levels indicating passage of 8000V Human Body Model. |
Vibration Test |
N/A Vibrate randomly along three perpendicular directions for 30 minutes in each direction, 4 cycles from 20~2000 Hz with a peak acceleration of 20 Gs. |
Drop Test |
N/A Drop samples from 1.5 m height onto a steel surface, total 18 times and inspected for mechanical damage. |
Shock Test |
N/A Subject samples to half-sine shock pulses (3000 ±15 % Gs for 0.3 ms) in each direction, for a total of 18 shocks. |
Operation Life |
N/A Subject samples to +125 ºC for 168 hours under full maximum rated voltage |
- 1 0 dB=1 V/Pa
- 2 0 dB=1 V/Pa
- 3 1 kHz, 94 dB Input, A-Weighted
- 4 0 dB=1 V/Pa, 3.6 to 1.5 VDC
- 5 94 dB at 50 cm, 1 kHz
- 6 50 cm, 1 kHz, 10% THD
- 7 PSR, 100 mVpp Square Wave at 217 Hz, A-Weighted
- 8 MSL level dependent on product remaining in sealed packaging until use
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok