Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A PUI Audio™

Manufacturer

N/A PUI Audio�, Inc.
Sensitivity (1 Kilohertz (kHz) Frequency at 50 Centimeter (cm))1 N/A -38 dB
Sensitivity Tolerance (±) (1 Kilohertz (kHz) Frequency at 50 Centimeter (cm))2 N/A 1 dB

Direct Current (DC) Rated Voltage

N/A 2 V

Direct Current (DC) Operating Voltage Range

N/A 1.5 to 3.6 V

Output Impedance at 1 Kilohertz (kHz) Frequency

N/A 300 Ω

Current Consumption at 2 Volts (V) Direct Current (DC) Voltage

N/A 130 µA

Current Consumption at 3.6 Volts (V) Direct Current (DC) Voltage

N/A 150 µA
Signal to Noise Ratio3 N/A 64 dB
Decreasing Voltage4 N/A 0.5 dB

Frequency Range

N/A 20 to 20000 Hz
Total Harmonic Distortion5 N/A 0.5 %
Acoustic Overload Point (AOP) Sound Pressure Level (SPL)6 N/A 123 dB

Directivity

N/A Omni-Directional

Acceptable Soldering Methods

N/A Reflow Solder

Environmental Compliances

N/A Halogen Free Restriction of Hazardous Substances (RoHS)
Power Supply Rejection7 N/A -98 dB

Weight

N/A < 0.3 g

Operating Temperature (VDD < 3 VDC)

N/A -40 ~ +100 ºC

Operating Temperature (VDD > 3 VDC)

N/A -40 ~ +70 ºC

Storage Temperature

N/A -40 ~ 125 ºC
Moisture Sensitivity Level (MSL)8 N/A 1

Absolute Maximum Ratings

Maximum Direct Current (DC) Voltage on Any Pin

N/A 4 V

Maximum Sound Pressure Level

N/A 160 dB

Maximum Mechanical Shock

N/A 10000 G

Maximum Vibration

N/A Pre-MIL-STD-883 Method 2007, Test Condition B

Reliability Testing

Simulated Reflow (Without Solder)

N/A Samples for qualification testing require 3 passes 260 ±5 ºC reflow solder profiles. 2 hours of setting time is required between each reflow profile test.

Static Humidity

N/A Precondition at +25 ºC for 1 hour. Expose to +85 ºC with 85% relative humidity for 1000 hours. Finally, dry at room ambient for 3 ±1 hour before taking final measurement.

Temperature Shock

N/A Each cycle shall consist of 30 minutes at -40 ºC, 30 minutes at +125 ºC with 5 minutes transition time. Test duration is for 30 cycles, starting from cold to hot temperature.

Electrostatic-Sensitive Device (ESD) Sensitivity

N/A Perform ESD sensitivity threshold measurements for each contact according to MIL-STD-883G, Method 3015.7 for Human Body Model. Identify the ESD threshold levels indicating passage of 8000V Human Body Model.

Vibration Test

N/A Vibrate randomly along three perpendicular directions for 30 minutes in each direction, 4 cycles from 20~2000 Hz with a peak acceleration of 20 Gs.

Drop Test

N/A Drop samples from 1.5 m height onto a steel surface, total 18 times and inspected for mechanical damage.

Shock Test

N/A Subject samples to half-sine shock pulses (3000 ±15 % Gs for 0.3 ms) in each direction, for a total of 18 shocks.

Operation Life

N/A Subject samples to +125 ºC for 168 hours under full maximum rated voltage

Note

Note

N/A Microphone frequency response and sensitivity shall not deviate more than ±3 dB.
  • 1 0 dB=1 V/Pa
  • 2 0 dB=1 V/Pa
  • 3 1 kHz, 94 dB Input, A-Weighted
  • 4 0 dB=1 V/Pa, 3.6 to 1.5 VDC
  • 5 94 dB at 50 cm, 1 kHz
  • 6 50 cm, 1 kHz, 10% THD
  • 7 PSR, 100 mVpp Square Wave at 217 Hz, A-Weighted
  • 8 MSL level dependent on product remaining in sealed packaging until use