PUI Audio?'s unidirectional electret condenser microphones (ECMs) also known as cardioid microphones are purpose-built to only capture sound from one direction. Four holes on the rear of the microphone capsule focus the sweet spot of the microphone's polar pattern to directly in front of the microphone.
Excellent for use in recording a single acoustic source, unidirectional microphones are great as boom microphones to record sound at distance, rejecting unwanted noise, or are used in pairs for two-channel stereo recording.
Excellent for use in recording a single acoustic source, unidirectional microphones are great as boom microphones to record sound at distance, rejecting unwanted noise, or are used in pairs for two-channel stereo recording.
Unit of Measure
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Directivity |
N/A Unidirectional |
Note for Directivity |
N/A Minimum -12 dB drop in output at 180º±20º at 1 kHz |
Sensitivity |
N/A -50 dB |
Sensitivity Tolerance (±) |
N/A 4 dB |
Testing Condition for Sensitivity |
N/A
1 kHz at 50 cm 0 dB=1V/Pa |
Direct Current (DC) Rated Voltage |
N/A 2 V |
Output Impedance at 1 Kilohertz (kHz) Frequency |
N/A 0.68 kΩ |
Current Consumption |
N/A 500 µA |
Note for Current Consumption |
N/A 3VS with 2.2 kΩ RL |
Signal to Noise Ratio |
N/A > 55 dB |
Note for Signal to Noise Ratio |
N/A 1 kHz, 94 dB input, A-Weighted |
Decreasing Voltage |
N/A -3 V |
Note for Decreasing Voltage |
N/A 2VS to 1.5VS |
Frequency Range1 | N/A 20 ~ 20000 Hz |
Testing Condition for Frequency Range |
N/A At 50 cm, -10 dB |
Direct Current (DC) Operating Voltage Range |
N/A 1 ~ 10 V |
Maximum Sound Pressure Level (SPL) Input (Total harmonic distortion (THD) < 3 Percent (%)) |
N/A 110 dB |
Operating Temperature |
N/A -20 ~ +60 ºC |
Storage Temperature |
N/A -40 ~ +70 ºC |
Weight |
N/A < 0.3 g |
Height |
N/A 5 mm |
Diameter |
N/A 6 mm |
Diameter Tolerance (±) |
N/A 0.1 mm |
Angle Tolerance (±) |
N/A 3 º |
Industry Standards |
N/A Restriction of Hazardous Substances (RoHS) 2011/65/EU |
Reliability Testing
High Temperature Test |
N/A 200 hours at +60 ºC ± 3 ºC followed by two hours in normal room temperature |
Low Temperature Test |
N/A 200 hours at -20 ºC ± 3 ºC followed by two hours in normal room temperature |
Humidity Test |
N/A 200 hours at +40 ºC ± 3 ºC with relative humidity at 90% to 95% followed by 2 hours in normal room temperature |
Temperature Cycle Test |
N/A 30 minutes at -25 ºC, 10 minutes at 20 ºC, 30 minutes at +70 ºC, 10 minutes at 20 ºC for five cycles, followed by 2 hours in normal room temperature |
Vibration Test |
N/A 10-55 Hz for 1 minute with 1.52 mm distance, followed by a two-hour 3 axis test in packaging |
Drop Test |
N/A Drop microphones in packaging onto concrete floor from 1-meter height in each of 3-axis |
Electrostatic Discharge (ESD) Test |
N/A
|
Note for Reliability Testing |
N/A After each test, the speaker's SPL shall be ±3 dB of the original SPL |