PUI Audio??s all-new HD Series microphones use premium-grade FETs and diaphragms for high sensitivity and superior signal-to-noise ratio. Each microphone features GSM buzz-blocking capacitors. Upgrade the ECM microphone that you use today with a PUI Audio HD Series microphone.
The 8 mm diameter DOM-3027L-HD-R is designed for extreme fidelity, in even the quietest settings, from 20 Hz to 20 kHz.
The 8 mm diameter DOM-3027L-HD-R is designed for extreme fidelity, in even the quietest settings, from 20 Hz to 20 kHz.
Unit of Measure
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio� Inc. |
Sensitivity |
N/A -27 dB |
Sensitivity Tolerance (±) |
N/A 3 dB |
Testing Condition for Sensitivity |
N/A
1 kHz at 50 cm 0 dB=1V/Pa |
Direct Current (DC) Rated Voltage |
N/A 3 V |
Output Impedance at 1 Kilohertz (kHz) Frequency |
N/A 2.2 kΩ |
Current Consumption |
N/A 500 µA |
Note for Current Consumption |
N/A 3VS with 2.2 kΩ RL |
Signal to Noise Ratio |
N/A 77 dB |
Note for Signal to Noise Ratio |
N/A 1 kHz, 94 dB input, A-Weighted |
Decreasing Voltage |
N/A -3 dB |
Note for Decreasing Voltage |
N/A 3VS to 2VS |
Frequency Range |
N/A 20 ~ 20000 Hz |
Direct Current (DC) Operating Voltage Range |
N/A 1 ~ 10 V |
Maximum Sound Pressure Level (SPL) Input (Total harmonic distortion (THD) < 3 Percent (%)) |
N/A 110 dB |
Directivity |
N/A Omni-Directional |
Operating Temperature |
N/A -20 ~ +70 ºC |
Storage Temperature |
N/A -40 ~ +85 ºC |
Weight |
N/A < 0.3 g |
Diameter |
N/A 8 mm |
Height |
N/A 3 mm |
Tolerance (±) |
N/A 0.5 mm |
Angle Tolerance (±) |
N/A 3 º |
Industry Standards |
N/A Restriction of Hazardous Substances (RoHS) 2011/65/EU |
Reliability Testing
High Temperature Test |
N/A 200 hours at +70 ºC ± 3 ºC followed by two hours in normal room temperature |
Low Temperature Test |
N/A 200 hours at -25 ºC ± 3 ºC followed by two hours in normal room temperature |
Humidity Test |
N/A 200 hours at +40 ºC± 3 ºC with relative humidity at 90 % to 95 % followed by 2 hours in normal room temperature |
Temperature Cycle Test |
N/A 30 minutes at -25 ºC, 10 minutes at 20 ºC, 30 minutes at +70 ºC, 10 minutes at 20 ºC for five cycles, followed by 2 hours in normal room temperature |
Vibration Test |
N/A 10-55 Hz for 1 minute with 1.52 mm distance, followed by a two-hour 3 axis test in packaging |
Drop Test |
N/A Drop microphones in packaging onto concrete floor from 1 meter height in each of 3 axis |
Electrostatic Discharge (ESD) Test |
N/A
|
Note Electrostatic Discharge (ESD) Test |
N/A According to IEC 6100 |
Note for Reliability Testing |
N/A After each test, the speaker's SPL shall be ±3 dB of the original SPL |