Unit of Measure
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A PUI Audio™ |
Manufacturer |
N/A PUI Audio�, Inc. |
Directivity |
N/A Omni-Directional |
Data Format |
N/A 1/2 Cycle PDM |
Sensitivity |
N/A -26 dB |
Sensitivity Tolerance (±) |
N/A 1 dB |
Testing Condition for Sensitivity |
N/A 1 kHz at 50 cm with 94 dB source 0 dB=1 V/Pa |
Direct Current (DC) Rated Voltage |
N/A 1.8 V |
Direct Current (DC) Operating Voltage Range |
N/A 1.6 to 3.6 V |
Current Draw at Full Power Mode |
N/A 800 ~ 1000 µA |
Current Draw at Low Power Mode |
N/A 400 ~ 450 µA |
Signal to Noise Ratio at Full Power Mode |
N/A 58 dB |
Signal to Noise Ratio at Low Power Mode |
N/A 56 dB |
Note for Signal to Noise Ratio |
N/A 1 kHz, 94 dB input, A-Weighted |
Frequency Range (-10 dB) |
N/A 20 ~ 15000 Hz |
Total Typical Harmonic Distortion |
N/A 0.5 % |
Testing Condition for Total Typical Harmonic Distortion |
N/A 94 dB at 50 cm, 1 kHz acoustic source |
Load Capacitance |
N/A 140 pF |
Acceptable Soldering Methods |
N/A Reflow Solder |
Acoustic Overload Point (AOP) at Full Power Mode |
N/A 123 dB |
Acoustic Overload Point (AOP) at Low Power Mode |
N/A 120 dB |
Testing Condition for Acoustic Overload Point (AOP) at Low Power Mode |
N/A 10 % THD at 1 kHz, acoustic source 50cm away from microphone |
Environmental Compliances |
N/A Restriction of Hazardous Substances (RoHS)/Halogen Free |
Power Supply Rejection1 | N/A -80 dB |
Testing Condition for Power Supply Rejection |
N/A 100 mVpp Square Wave at 217 Hz, A-Weighted |
Weight |
N/A < 0.3 g |
Maximum Direct Current (DC) Voltage on Any Pin |
N/A 4 V |
Maximum Sound Pressure Level (SPL) Before Damage (Source 50 cm From Microphone) |
N/A 160 dB |
Maximum Mechanical Shock |
N/A 10000 G |
Maximum Vibration |
N/A Pre-MIL-STD-883 Method 2007, Test Condition B |
Operating Temperature (VDD < 3 VDC) |
N/A -40 ~ +100 ºC |
Operating Temperature (VDD > 3 VDC) |
N/A -40 ~ +70 ºC |
Storage Temperature |
N/A -40 ~ +125 ºC |
Ingress Protection Rating |
N/A Ingress Protection (IP57) |
Moisture Sensitivity Level (MSL)2 | N/A 1 |
Clock Frequency at Sleep Mode |
N/A 0 ~ 320 kHz |
Clock Frequency at Low Power Mode |
N/A 351 ~ 800 kHz |
Clock Frequency at Full Power Mode |
N/A 1.024 ~ 4.096 MHz |
Duty Cycle |
N/A 45 ~ 55 % |
Testing Condition for Duty Cycle |
N/A For fCLK ≤ 2.4 MHz the duty cycle must be in the range of 40 ~ 60% and for fCLK > 2.4 MHz the duty cycle must be 50% |
Tolerance (±) |
N/A 0.5 mm |
Angle Tolerance (±) |
N/A 3 º |
Operational Settings
High Logic Input |
N/A 0.65 x VDD ~ VDD + 0.3V |
Low Logic Input |
N/A -0.3 ~ 0.35 x VDD |
High Logic Output |
N/A 0.65 x VDD ~ VDD + 0.3V |
Low Logic Output |
N/A -0.3 ~ 0.35 x VDD |
Reliability Testing
Simulated Reflow (Without Solder) |
N/A Samples for qualification testing require 3 passes 260±5 ºC reflow solder profiles. 2 hours of setting time is required between each reflow profile test. |
Static Humidity |
N/A Precondition at +25 ºC for 1 hour. Expose to +85 ºC with 85% relative humidity for 1000 hours. Dry at room ambient for 3±1 hour before taking final measurement. |
Temperature Shock |
N/A Each cycle shall consist of 30 minutes at -40 ºC, 30 minutes at +125 ºC with 5 minutes transition time. Test duration is for 30 cycles, starting from cold to hot temperature. |
Electrostatic-Sensitive Device (ESD) Sensitivity |
N/A Perform ESD sensitivity threshold measurements for each contact according to MIL-STD-883G, Method 3015.7 for Human Body Model. Identify the ESD threshold levels indicating passage of 8000V Human Body Model. |
Vibration Test |
N/A Vibrate randomly along three perpendicular directions for 30 minutes in each direction, 4 cycles from 20~2000 Hz with a peak acceleration of 20 Gs. |
Shock Test |
N/A Subject samples to half-sine shock pulses (3000±15% Gs for 0.3ms) in each direction, for a total of 18 shocks. |
Drop Test |
N/A Drop samples from 1.5m height onto a steel surface, total 18 times and inspected for mechanical damage. |
Operation Life |
N/A Subject samples to +125ºC for 168 hours under full maximum rated voltage. |
Waterproof Test |
N/A Place 15 microphones in water at 1m depth for 30 minutes. Remove and dissect 5 pieces to check for water ingress. Test remaining 10 microphones for sensitivity after resting at room temperature for 2 hours. |
Note for Reliability Testing |
N/A Microphone frequency response and sensitivity shall not deviate more than ±3 dB. |
- 1 To Full Scale
- 2 MSL level dependent on product remaining in sealed packaging until use.
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok