Unit of Measure
Specifications
|
Absolute Maximum Ratings (TA = 25 Degree Celsius (ºC) Temperature)
|
Electrical/Optical Characteristics (Ta = 25 Degree Celsius (ºC)
|
Applications
|
Features
|
Note
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A SunLED |
Manufacturer |
N/A SunLED |
Emitting Color |
N/A Red |
Emitting Material |
N/A Aluminum Gallium Indium Phosphide (AlGaInP) |
Lens Color |
N/A Water Clear |
Minimum Luminous Intensity at IF=20 Milliampere (mA) Current for Code Y |
N/A 2300 mcd |
Maximum Luminous Intensity at IF=20 Milliampere (mA) Current for Code Y |
N/A 2700 mcd |
Minimum Luminous Intensity at IF=20 Milliampere (mA) Current for Code Z |
N/A 2700 mcd |
Maximum Luminous Intensity at IF=20 Milliampere (mA) Current for Code Z |
N/A 3100 mcd |
Minimum Luminous Intensity at IF=20 Milliampere (mA) Current for Code ZA |
N/A 3100 mcd |
Maximum Luminous Intensity at IF=20 Milliampere (mA) Current for Code ZA |
N/A 3600 mcd |
Minimum Luminous Intensity at IF=20 Milliampere (mA) Current for Code ZB |
N/A 3600 mcd |
Maximum Luminous Intensity at IF=20 Milliampere (mA) Current for Code ZB |
N/A 4200 mcd |
Minimum Luminous Intensity at IF=20 Milliampere (mA) Current for Code ZC |
N/A 4200 mcd |
Maximum Luminous Intensity at IF=20 Milliampere (mA) Current for Code ZC |
N/A 5000 mcd |
Minimum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code T |
N/A 700 mcd |
Maximum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code T |
N/A 1000 mcd |
Minimum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code U |
N/A 1000 mcd |
Maximum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code U |
N/A 1300 mcd |
Minimum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code V |
N/A 1300 mcd |
Maximum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code V |
N/A 1600 mcd |
Minimum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code W |
N/A 1600 mcd |
Maximum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code W |
N/A 1900 mcd |
Minimum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code X |
N/A 1900 mcd |
Maximum Luminous Intensity with CIE127-2007 at IF= 20 Milliampere (mA) Current for Code X |
N/A 2300 mcd |
Note for Luminous Intensity and Wavelength |
N/A Luminous intensity value and wavelength are in accordance with CIE127-2007 standards. |
Viewing Angle (2 θ 1/2)1 | N/A 20 º |
Luminous Intensity (±) |
N/A 15 % |
Luminous Flux (±) |
N/A 15 % |
Moisture Sensitivity Level (MSL) |
N/A 3 |
Units Per Package |
N/A 1000 |
Package Type |
N/A Reel |
Industry Standards |
N/A Restriction of Hazardous Substances (RoHS) Compliant |
Absolute Maximum Ratings (TA = 25 Degree Celsius (ºC) Temperature)
Power Dissipation (PD) |
N/A 75 mW |
Junction Temperature (TJ) |
N/A 5 ºC |
Reverse Voltage (VR) |
N/A 115 V |
Operating Temperature (TA) |
N/A -40 to +100 ºC |
Storage Temperature Range (TSTG) |
N/A -40 to +115 ºC |
Direct Forward Current (IF)2 | N/A 30 mA |
Peak Forward Current (IFM)3 | N/A 185 mA |
Electrostatic Discharge Threshold (HBM) |
N/A 3000 V |
Thermal Resistance Junction/Ambient (Rth(j-a))4 | N/A 330 ºC/W |
Electrical/Optical Characteristics (Ta = 25 Degree Celsius (ºC)
Typical Wavelength of Peak Emission with CIE127-2007 (λP) at IF=20 Milliampere (mA) Current |
N/A 645 nm |
Minimum Wavelength of Dominant Emission with CIE127-2007 (λD) at IF=20 Milliampere (mA) Current |
N/A 620 nm |
Maximum Wavelength of Dominant Emission with CIE127-2007 (λD) at IF=20 Milliampere (mA) Current |
N/A 640 nm |
Wavelength of Dominant Emission with CIE127-2007 (λD) Tolerance (±) |
N/A 1 nm |
Typical Reverse Current (IR) at VR= 5 Volt (V) Voltage |
N/A 10 µA |
Typical Spectral Bandwidth (Δλ) at 50 Percent (%) FREL Maximum IF=20 Milliampere (mA) Current |
N/A 28 nm |
Minimum Forward Voltage (VF) at IF=20 Milliampere (mA) Current |
N/A 1.6 V |
Typical Forward Voltage (VF) at IF=20 Milliampere (mA) Current |
N/A 1.95 V |
Maximum Forward Voltage (VF) at IF=20 Milliampere (mA) Current |
N/A 2.5 V |
Typical Temperature Coefficient of Peak Wavelength (λpeak) (TClpeak)5 | N/A 0.14 nm/ºC |
Typical Temperature Coefficient of Dominant Wavelength (λdom) (TCldom)6 | N/A 0.05 nm/ºC |
Typical Temperature Coefficient of Forward Voltage (VF) (TCv)7 | N/A -2.4 mV/ºC |
Forward Voltage Tolerance (±) |
N/A 0.1 V |
Applications
Applications |
N/A
|
- 1 θ 1/2 is the angle from optical centerline where the luminous intensity is 1/2 of the optical peak value.
- 2 Rth(j-a) Results from mounting on PC board FR4 (pad size ≥16 mm² per pad).
- 3 1/10 Duty Cycle, 0.1 ms Pulse Width.
- 4 Rth(j-a) Results from mounting on PC board FR4 (pad size ≥16 mm² per pad).
- 5 At IF = 20 mA, -10 ºC ≤ T ≤ 100 ºC
- 6 At IF = 20 mA, -10 ºC ≤ T ≤ 100 ºC
- 7 At IF = 20 mA, -10 ºC ≤ T ≤ 100 ºC
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok