Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A APEM

Manufacturer

N/A APEM

Series

N/A QRM-NV

Mounting Hole Diameter

N/A 8 mm

Terminals

N/A Wires

Bezel Finish

N/A Black Chrome

Type of Illumination

N/A Fixed Light

Light Emitting Diode (LED) Color

N/A Near Vertical Incidence Skywave (NVIS) Green A

Direct Current (DC) Voltage

N/A 24 V

Sealing

N/A Standard Ingress Protection (IP67)

Electrical Specifications

Operating Direct Current (DC) Voltage

N/A 25.2 to 30.8 V

Maximum Operating Direct Current (DC)

N/A 20 mA

Near Vertical Incidence Skywave (NVIS) Radiance

N/A NRA 1.7eE-10 at 0.1 Foot-lambert (fL)

Near Vertical Incidence Skywave (NVIS) Chromaticity

N/A r ≤ 0.037

Dominant Wavelength

N/A 530 nm

Standard Light Emitting Diode (LED) Intensity

N/A 150 mcd

Near Vertical Incidence Skywave (NVIS) Green A Forward Voltage

N/A 3.3 V

Environmental Specifications

Operating Temperature Range

N/A -40 to 85 ºC-40 to 185 ºF

Storage Temperature Range

N/A -55 to 100 ºC-67 to 212 ºF

General Specifications

Maximum Reverse Voltage (VR)

N/A 5 V

Viewing Angle

N/A 60 º

Note for Life Expectancy

N/A 100000 hours

Maximum Panel Thickness

N/A 3.5 mm

Torque

N/A 60 cNm

Insulation Resistance at 500 Volt (V) Direct Current (DC) Voltage

N/A 4000 MΩ

Salt Spray Test

N/A 96 Hours (h) (International Electrotechnical Commission (IEC 68-2-11))

Materials

Body Material

N/A Anodized Aluminum Black Plated Brass

Lock Washer Material

N/A Spring Steel

Nut Material

N/A Black Plated Brass

Terminal Seal Material

N/A Epoxy

Panel Seal Material

N/A Nitrile O-Ring

Wires Material

N/A 24 American Wire Gauge (AWG) Approved to Underwriter Laboratories (UL1213)

Features

Features

N/A
  • NVIS Green A, NVIS Green B, NVIS Yellow, NVIS Red, NVIS White
  • NVIS compliant to MIL Std 3009
  • 200 mm wire for Ø 8 and 14 mm or rigid pin (1.00 mm) for Ø 8 mm terminations

Note

Note

N/A The company reserves the right to change specifications without notice.

LED characteristics are dependent upon environmental conditions. Therefore published data should be considered nominal and subject to variations.
  • The operating voltage must not be exceeded by more that 10% as this will result in reduced life expectancy.
  • Luminous intensity is measured at 20 mA on a discrete led unless otherwise stated.
  • Luminous intensities and color shades of white LEDs may vary within a batch.
  • Luminous intensity will be reduced with lower operating current.