- Delta will not guarantee the performance of the products if the application condition falls outside the parameters set forth in the specification.
- A written request should be submitted to Delta prior to approval if deviation from this specification is required.
- Please exercise caution when handling fans. Damage may be caused when pressure is applied to the impeller, if the fans are handled by the lead wires, or if the fans are hard-dropped to the production floor.
- Except as pertains to some special designs, there is no guarantee that the products will be free from any such safety problems or failures as caused by the introduction of powder, droplets of water or encroachment of insect into the hub.
Unit of Measure
Specifications
|
Life Expectance L10 (At Label Voltage)
|
Mechanical Specifications
|
Environmental
|
Protection
|
Additional Information
|
Note
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Maximum Air Pressure at Zero Air Flow |
N/A 53.631 mmH2O2.111 inH2O |
Brands |
N/A Delta |
Manufacturer |
N/A Delta Electronics |
Direct Current (DC) Rated Voltage |
N/A 12 V |
Operating Direct Current (DC) Voltage |
N/A 5.5 to 13.2 V |
Minimum Input Current |
N/A 0.65 A |
Maximum Input Current |
N/A 0.81 A |
Minimum Input Power |
N/A 7.80 W |
Maximum Input Power |
N/A 9.72 W |
Reference Speed |
N/A 18500 rpm |
Minimum Air Flow at Zero Static Pressure |
N/A 0.689 m³/min24.347 ft³ |
Maximum Air Flow at Zero Static Pressure |
N/A 0.766 m³/min27.053 ft³ |
Minimum Air Pressure at Zero Air Flow |
N/A 43.441 mmH2O1.710 inH2O |
Minimum Average Acoustical Noise |
N/A 58.5 dBA |
Maximum Average Acoustical Noise |
N/A 62.5 dBA |
Insulation Type |
N/A Class A |
Minimum Insulation Strength at 500 Volt (V) Direct Current (DC) Voltage1 | N/A 10 MΩ |
Maximum Dielectric Strength at 500 Alternating Current (AC) Voltage and 60 Hertz (Hz) Frequency2 | N/A 5 mA |
External Cover |
N/A Open Type |
Rotation |
N/A Clockwise View From Name Plate Side |
Over Current Shut Down |
N/A The current will shut down when locking rotor. |
Lead Wire |
N/A
UL 1061 -F - American Wire Gauge (AWG) #26 Black Wire Negative (-) Red Wire Positive (+) Blue Wire Frequency (-F00) |
Re Ozone Depleting Substances |
N/A No containing PBBs, PBBOs, CFCs, PBBEs, PBDPEs, and HCFCs. |
Production Location |
N/A Products will be produced in China or Thailand or Taiwan. |
Caution |
N/A
The lead wire of FG signal can not touch The lead wire of positive or negative |
Maximum Frequency Generator (FG) Voltage |
N/A 13.2 V |
Maximum Collector Current |
N/A 5 mA |
Maximum Collector Emitter Voltage |
N/A 0.5 V |
Industry Standards |
N/A European Conformity (CE) Marked Underwriters Laboratories (UL) 94V-0 |
Life Expectance L10 (At Label Voltage)
Continuous Operation Time |
N/A 70000 hours |
Continuous Operation Temperature |
N/A 40 ºC |
Relative Humidity |
N/A 15 ~ 65 % |
Mechanical Specifications
Frame Material |
N/A Plastic |
Impeller Material |
N/A Plastic |
Bearing System |
N/A Dual Ball Bearings |
Weight |
N/A 47 g |
Environmental
Operating Temperature |
N/A -10 to 70 ºC |
Storage Temperature |
N/A -40 to 80 ºC |
Operating Relative Humidity |
N/A 5 to 90 % |
Storage Relative Humidity |
N/A 5 to 95 % |
Protection
Locked Rotor Protection |
N/A Impedance of motor winding protects motor from fire in 96 hours of locked rotor condition at the rated voltage. |
Polarity Protection |
N/A Be capable of withstanding if reverse connection for positive and negative leads. |
Additional Information
Additional Information |
N/A
|
Note
Note |
N/A
|
- 1 (Between Frame and (+) Terminal)
- 2 One Minute, (Between Frame and (+) Terminal)