  1. Delta will not guarantee the performance of the products if the application condition falls outside the parameters set forth in the specification.
  2. A written request should be submitted to Delta prior to approval if deviation from this specification is required.
  3. Please exercise caution when handling fans. Damage may be caused when pressure is applied to the impeller, if the fans are handled by the lead wires, or if the fans are hard-dropped to the production floor.
  4. Except as pertains to some
more
Unit of Measure

Specifications

Available

Manufacturer Stock

Brands

Delta

Manufacturer

Delta Electronics

Direct Current (DC) Rated Voltage

12 V

Operating Direct Current (DC) Voltage

7 to 15 V

Minimum Input Current

0.43 A

Maximum Input Current

0.52 A

Minimum Input Power

5.16 W

Maximum Input Power

6.24 W

Speed at Room Temperature

15600 rpm

Speed Tolerance (±) at Room Temperature

10 %

Minimum Air Flow at Zero Static Pressure

0.524 m³/min18.50 ft³

Maximum Air Flow at Zero Static Pressure

0.582 m³/min20.56 ft³

Minimum Air Pressure at Zero Air Flow

28.48 mmH2O1.121 inH2O

Maximum Air Pressure at Zero Air Flow

35.16 mmH2O1.385 inH2O

Minimum Average Acoustical Noise

52 dBA

Maximum Average Acoustical Noise

56 dBA

Insulation Type

Underwriters Laboratories (UL): Class A

Current on Label

0.60 A

Ingress Protection

IP55
Minimum Insulation Strength at 500 Volt (V) Direct Current (DC) Voltage1 10 MΩ
Maximum Dielectric Strength at 500 Alternating Current (AC) Voltage and 50/60 Hertz (Hz) Frequency2 5 mA

External Cover

Open Type

Rotation

Clockwise View From Name Plate Side

Lead Wire

Wire Strip UL:1430 American Wire Gauge (AWG) #28
Red Wire (+)
Black Wire (-)

Wire Strip UL:1061 AWG#28
Yellow Wire - (PWM)
Blue Wire (-F00)

Re Ozone Depleting Substances

No containing PBBs, PBBOs, CFCs, PBBEs, PBDPEs, and HCFCs.

Production Location

Products will be produced in China or Thailand or Taiwan.

Maximum Direct Current (DC) Frequency Generator (FG) Voltage

15 V

Maximum Collector Current

5 mA

Maximum Saturated Collector Emitter Voltage

0.5 V

Duty Cycle

100 %

Industry Standards

European Conformity (CE) Marked Underwriters Laboratories (UL) 94V-0

Caution

The FG signal lead wire must be kept away from "+" lead wire and "-" lead wire

Life Expectance L10 (At Label Voltage)

Continuous Operation Time

70000 hours

Continuous Operation Temperature

40 ºC

Relative Humidity

15 ~ 65 %

Mechanical Specifications

Frame Material

Plastic

Impeller Material

Plastic

Bearing System

Dual Ball Bearings

Weight

25 g

Environmental

Operating Temperature

-25 to 70 ºC

Storage Temperature

-40 to 75 ºC

Operating Relative Humidity

5 to 90 %

Storage Relative Humidity

5 to 95 %

Protection

Locked Rotor Protection

Protects motor from fire in 96 hours of locked rotor condition at the rated voltage.

Polarity Protection

Be capable of withstanding if reverse connection for positive and negative leads.

Pulse Width Modulation (PWM) Signal

Pulse Width Modulation (PWM) Signal

  • The frequency for control signal of the fan shall be able to accept a 1 KHz.
  • The preferred operating point for the fan is 1 KHz.
  • At 100 % duty cycle, the rotor will spin at maximum speed.
  • At 0 % duty cycle, the rotor will stop spinning.
  • With control signal lead disconnected, the fan will spin at maximum speed.
  • At DC 12 V , 1 KHz 30 % duty cycle ,the fan will be able to start from a dead stop .

Additional Information

Additional Information

  • The above-mentioned conditions are representative of some unique examples and viewed as the first point of reference prior to all other information.
  • It is very important to establish the correct polarity before connecting the fan to the power source. Positive (+) and Negative (-). Damage may be caused to the fans if connection is with reverse polarity, as there is no foolproof method to protect against such error.
  • Delta fans are not suitable where any corrosive fluids are introduced to their environment.
  • Please ensure all fans are stored according to the storage temperature limits specified. Do not store fans in a high humidity environment. We highly recommend performance testing is conducted before shipping, if the fans have been stored over 6 months
  • Not all fans are provided with the Lock Rotor Protection feature. If you impair the rotation of the impeller for the fans that do not have this function, the performance of those fans will lead to failure.
  • Please be cautious when mounting the fan. Incorrect mounting of fans may cause excess resonance, vibration and subsequent noise.
  • It is important to consider safety when testing the fans. A suitable fan guard should be fitted to the fan to guard against any potential for personal injury.
  • Except where specifically stated, all tests are carried out at relative (ambient) temperature and humidity conditions of 25 ºC, 65 %. The test value is only for fan performance itself.
  • Be certain to connect an "over 4.7 µF" capacitor to the fan externally when the application calls for using multiple fans in parallel, to avoid any unstable power.

Scope

Scope

This specification defines the electrical and mechanical characteristics of the DC Brushless Axial Flow Fan

Note

Note

  1. All readings are measured after stably warming up through 10 minutes.
  2. The values written in parens, ( ), are limited spec.
  3. Acoustical noise measuring condition:
Noise is measured at rated voltage in free air in anechoic chamber with B & K sound level meter with microphone at a distance of one meter from the fan intake.
  • 1 (Between Frame and (+) Terminal)
  • 2 One Minute, (Between Frame and (+) Terminal)