Unit of Measure

Specifications

Available

$1.00

Manufacturer Stock

0

Brands

Sanyo Denki

Rated Voltage

12 V

Operating Voltage Range

7 to 13.8 V

Rated Current

0.105 A

Rated Input Power

1.26 W

Rated Speed

6700 rpm

Maximum Air Flow

0.244 m³/min8.6 ft³/min

Maximum Static Pressure

58.8 Pa0.236 inH2O
Sound Pressure Level (SPL)1 30 dBA

Operating Temperature

-20 to 70 ºC
Expected Life at 60 Degree Celsius (ºC) Temperature2 60000 hours
Expected Life at 40 Degree Celsius (ºC) Temperature3 90000 hours

Frame Material

Plastic UL 94V-0

Impeller Material

Plastic UL 94V-1

Motor Protection Function

Locked Rotor Burnout Protection Reverse Polarity Protection
Dielectric Strength4 50/60 Hz, 500 VAC, for 1 minute
Minimum Insulation Resistance at 500 Volt (V) Direct Current (DC) Voltage5 10 MΩ
Storage Temperature6 -30 ~ +70 ºC

Lead Wire

Negative: Black or Blue

Positive: Red

Sensor: Yellow

Size

40 x 40 x 28 mm

Mass

52 g

Industry Standards

Canadian Standards Association (CSA®) Recognized Component Mark (RU®) TÜV Rheinland Certified

Note

Note

Sensor and Control Options are available for Selection.

Short Lead Time Service applicable Models.

  • 1 A-weighted sound pressure level (SPL) at 1 m away from the air inlet.
  • 2 L10 life: 90% survival rate for continuous operation in free air at 60 ºC, rated voltage.
  • 3 Expected life at 40 ºC is for reference only.
  • 4 Between lead wire conductors and frame
  • 5 Between lead wire conductors and frame
  • 6 Non-condensing