Our DC cooling fans have features such as high airflow, high reliability, and low noise. They can be used in a wide-ranging applications including servers and ICT equipment.

High Performance Achieved as Fruits of Our Technological Innovations

The San Ace DC Fans feature industry-leading high airflow, high static pressure, low power consumption, and low vibration. In the development phase, we thoroughly reviewed impeller shape, motor characteristics, operating airflow, and expected life tomore

Unit of Measure
Items
San Ace 40 9P Type 0.195 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.68 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.16 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.16 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.21 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.21 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.195 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.105 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.195 Ampere (A) Rated Current Fan

San Ace 40 9P Type 0.31 Ampere (A) Rated Current Fan
Manufacturer Stock
Description N/A The model have ribs and pulse sensors. N/A The model have ribs and pulse sensors. N/A The model have ribs and pulse sensors. N/A

The model have ribs and pulse sensors.

N/A The model have ribs and pulse sensors.
Brands N/A Sanyo Denki
Manufacturer N/A Sanyo Denki Co., Ltd.
Rated Voltage N/A 5 V N/A 5 V N/A 5 V N/A 12 V N/A 12 V
Direct Current (DC) Rated Voltage N/A
Operating Voltage Range N/A 4.5 to 5.5 V N/A 4.5 to 5.5 V N/A 4.5 to 5.5 V N/A 7 to 13.8 V N/A 7 to 13.2 V
Operating Direct Current (DC) Voltage N/A
Rated Current N/A 0.68 A N/A 0.16 A N/A 0.21 A N/A 0.105 A N/A 0.31 A
Maximum Rated Current at 12 Volt (V) Direct Current (DC) Voltage N/A
Maximum Rated Current at 24 Volt (V) Direct Current (DC) Voltage N/A
Rated Input Power N/A 3.4 W N/A 0.8 W N/A 1.05 W N/A 1.26 W N/A 3.72 W
Rated Speed N/A 8700 rpm N/A 6200 rpm N/A 6500 rpm N/A 6700 rpm N/A 11500 rpm
Nominal Rated Speed at 12 Volt (V) Direct Current (DC) Voltage and 25 Degree Celsius (ºC) Temperature N/A
Nominal Rated Speed at 24 Volt (V) Direct Current (DC) Voltage and 25 Degree Celsius (ºC) Temperature N/A
Maximum Air Flow N/A 0.32 m³/min11.3 ft³/min N/A 0.15 m³/min5.3 ft³/min N/A 0.15 m³/min5.3 ft³/min N/A 0.244 m³/min8.6 ft³/min N/A 0.42 m³/min14.8 ft³/min
Maximum Static Pressure N/A 102.9 Pa0.414 inH2O N/A 41.2 Pa0.165 inH2O N/A 52.9 Pa0.213 inH2O N/A 58.8 Pa0.236 inH2O N/A 179 Pa0.719 inH2O
Sound Pressure Level (SPL)1 N/A 37 dBA N/A 25 dBA N/A 24 dBA N/A 30 dBA N/A 42 dBA
Nominal Sound Pressure Level (SPL)2 N/A
Operating Temperature N/A -20 to +70 ºC N/A -10 to +60 ºC N/A -20 to +60 ºC N/A -20 to +70 ºC N/A -20 to +60 ºC
Expected Life at 60 Degree Celsius (ºC) Temperature3 N/A 40000 hours N/A 40000 hours N/A 60000 hours N/A 60000 hours N/A 40000 hours
Expected Life at 40 Degree Celsius (ºC) Temperature4 N/A 70000 hours N/A 70000 hours N/A 90000 hours N/A 90000 hours N/A 70000 hours
Frame Material N/A Plastic UL 94V-0
Impeller Material N/A Plastic UL 94V-1
Bearing System N/A
Motor Protection Function N/A Locked Rotor Burnout Protection Reverse Polarity Protection
Dielectric Strength5 N/A 50/60 Hz, 500 VAC, for 1 minute
Minimum Insulation Resistance at 500 Volt (V) Direct Current (DC) Voltage6 N/A 10 MΩ
Storage Temperature7 N/A -30 to +70 ºC
Lead Wire N/A Negative: Black or Blue Positive: Red Sensor: Yellow N/A Negative: Black or Blue Positive: Red Sensor: Yellow N/A Negative: Black or Blue Positive: Red Sensor: Yellow N/A

Negative: Black or Blue

Positive: Red

Sensor: Yellow

N/A Negative: Black or Blue Positive: Red Sensor: Yellow
Size N/A 40 x 40 x 28 mm N/A 40 x 40 x 10 mm N/A 40 x 40 x 15 mm N/A 40 x 40 x 28 mm N/A 40 x 40 x 28 mm
Mass N/A 52 g N/A 19 g N/A 32 g N/A 52 g N/A 52 g
Approximate Mass N/A
Industry Standards N/A Canadian Standards Association (CSA®) Recognized Component Mark (RU®) TÜV Rheinland Certified
Note N/A
  1. Sensor and control options are available for selection.
  2. Short Lead Time Service applicable models.
N/A
  1. Sensor and control options are available for selection.
  2. Short Lead Time Service applicable models.
N/A
  1. Sensor and control options are available for selection.
  2. Short Lead Time Service applicable models.
N/A
  1. Sensor and control options are available for selection.
  2. Short Lead Time Service applicable models.
N/A
  1. Sensor and control options are available for selection.
  2. Short Lead Time Service applicable models.
  • 1 A-weighted sound pressure level (SPL) at 1 m away from the air inlet.
  • 2 Measured at 1 m distance from the air inlet.
  • 3 L10 life: 90% survival rate for continuous operation in free air at 60 ºC, rated voltage.
  • 4 Expected life at 40 ºC is for reference only.
  • 5 Between lead wire conductors and frame
  • 6 Between lead wire conductors and frame
  • 7 Non-condensing