• Radial Leads in Two Lengths
  • Flame Retardant Case Meets UL94V-0
  • Potting End Fill Meets UL94V-0
  • Used in applications where damage to the capacitor will not lead to the danger of electrical shock
Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A Cornell Dubilier

Manufacturer

N/A Cornell Dubilier

Series

N/A 158X

Capacitance

N/A 0.470 µF

Length (L)

N/A 1.181 in30 mm

Thickness (T)

N/A 0.433 in11 mm

Height (H)

N/A 0.866 in22 mm

Spacing (S)

N/A 1.083 in27.5 mm

Diameter (d)

N/A 0.031 in0.8 mm

Standard Capacitance Tolerance (±)

N/A 20 %

Special Capacitance Tolerance (±)

N/A 10 %

Rated Alternating Current (AC) Voltage

N/A 250 V275 V

Frequency Range

N/A 60 Hz

Operating Temperature Range

N/A -40 to +100 ºC

Maximum Dissipation Factor (Tgδ) with +25 Degree Celsius (ºC) Temperature at 1 Kilohertz (kHz) ±10 Hertz (Hz) Frequency

N/A 0.01

Maximum Pulse Rise Time

N/A 1000 V/µs

Lead Material

N/A Tinned Copper Clad Steel

Industry Standards

N/A Canadian Standards Association (CSA®) C22 2, No.1-98/No.8 (250VAC) Norges Elektriske Materiellkontroll (NEMKO) EN 60384-14 Underwriters Laboratories (UL-60384-14) Verband Deutscher Elektrotechniker (VDE) EN 60384-14

Insulation Resistance

Minimum Terminal to Terminal Insulation Resistance at 500 Volts (V) Direct Current (DC) Voltage and 20 Degree Celsius (ºC) Temperature

N/A 5000 MΩ·µF

Minimum Both Terminals to Body Insulation Resistance

N/A 100000 MΩ

Note

Note

N/A If ±10 % tolerance is required, add 'K' to end of Catalog Number.
Parts are normally supplied with leads 30 mm minimum.
To order short leads, 3.5 mm minimum length, add 'S' to end of Catalog Part Number.