Class X2 EMI/RFI Boxed
Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A Cornell Dubilier

Manufacturer

N/A Cornell Dubilier

Series

N/A MKP

Capacitance

N/A 4.7 µF

dv/dt Rating

N/A 100 V/µs

Lead Spacing (S)

N/A 37.5 mm

Lead Wire Diameter (d)

N/A 1 mm

Operating Temperature Range

N/A -40 to +110 ºC

Capacitance Tolerance (±) at 1 Kilohertz (kHz) Frequency, 20 Degree Celsius (ºC) Temperature

N/A 10 %

Maximum Dissipation Factor (Tan δ) at 1 Kilohertz (kHz) Frequency and 20 Degree Celsius (ºC) Temperature

N/A 0.1 %

Self-Inductance

N/A ≤ 1 Nano-Henry per mm of lead spacing and lead length

Impulse Voltage (24 Pulses)

N/A C ≤ 1 µF Vp= 2.5 kVDC
C > 1 µF Vp= 2.5 kV √C

Capacitance Temperature Coefficient

N/A ±100 ppm/ºC-200 ppm/ºC

Construction

N/A Metallized Polypropylene film

Electrodes

N/A Vacuum deposited Metal layers

Coating

N/A Flame retardant Solvent resistant plastic case with epoxy end fill (UL94V-0)

Lead Terminations

N/A Lead Free Tinned Copper Leads

Industry Standards

N/A Canadian Standards Association (CSA®) China Quality Certification (CQC) European Norms Electrical Certification (ENEC) Underwriters Laboratories (UL)

Dimensions

Dimension L

N/A 41.5 mm

Dimension H

N/A 30 mm

Dimension T

N/A 17.5 mm

Alternating Current (AC) Voltage

Alternating Current (AC) Voltage for Canadian Standards Association (CSA)

N/A 250 V310 V

Alternating Current (AC) Voltage for European Norms Electrical Certification (ENEC)

N/A 305 V

Alternating Current (AC) Voltage for China Quality Certification (CQC)

N/A 275 V

Alternating Current (AC) Voltage for Underwriters Laboratories (UL)

N/A 250 V310 V

Insulation Resistance at 20 Degree Celsius (ºC) (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volt (V) Direct Current Voltage (VDC) Applied

Terminal to Terminal Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volts (V) Direct Current (DC) Voltage Applied

N/A 5000 MΩ·µF

Terminal to Case Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volts (V) Direct Current (DC) Voltage Applied

N/A > 30000 MΩ

Terminal to Case Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 500 Volts (V) Direct Current (DC) Voltage Applied

N/A > 5000 MΩ

Dielectric Strength

Terminal to Terminal Dielectric Strength

N/A 1000 VAC 1768 VDC applied for 60 Seconds
Cut-off current: 2 A ac or 10 mAdc
Current limiting resistance: 1 O/V

Terminal to Case Dielectric Strength

N/A 2050 VDC applied between the terminals and case for 60 Seconds and 20 ºC

Life Expectancy

Note for Life Expectancy

N/A 1000 hours at 110 ºC at 125% of rated voltage with once every hour the voltage is increased to 1000 VAC for 0.1 seconds

Capacitance Change (Life Expectancy)

N/A ≤ 5 % of Initially Measured Value

Dissipation Factor Change (Life Expectancy)

N/A ≤ 0.15 % at 1 kHz

Insulation Resistance Change (Life Expectancy)

N/A ≥ 100 % of initially specified value (T-T)
≥ 3000 MO (Terminal to case)

Humidity Test

Note for Humidity Test

N/A 500 Hours at 90 to 95% RH, 40C and no voltage applied after which the following voltage will be applied for 1 minute to each capacitor.
C < 0.0068 µF 1500 VAC, C > 0.0068 µF 1075 VAC

Capacitance Change (Humidity Test)

N/A ≤ 5 % of Initially Measured Value

Dissipation Factor Change (Humidity Test)

N/A ≤ 0.15 % at 1 kHz

Insulation Resistance Change (Humidity Test)

N/A ≥ 50 % of initially specified value (T-T)
≥ 15000 MO (Terminal to case)

Features

Features

N/A
  • Metallized polypropylene
  • Low self-inductance
  • High dvdt
  • Small size
  • Low ESR

Applications

Applications

N/A
  • EMI Filter
  • Line by pass
  • Across the line
  • Antenna coupling