Class X2 EMI/RFI Boxed
Unit of Measure
Specifications
|
Dimensions
|
Alternating Current (AC) Voltage
|
Insulation Resistance at 20 Degree Celsius (ºC) (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volt (V) Direct Current Voltage (VDC) Applied
|
Dielectric Strength
|
Life Expectancy
|
Humidity Test
|
Features
|
Applications
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A Cornell Dubilier |
Manufacturer |
N/A Cornell Dubilier |
Series |
N/A MKP |
Capacitance |
N/A 0.047 µF |
dv/dt Rating |
N/A 300 V/µs |
Lead Spacing (S) |
N/A 15 mm |
Lead Wire Diameter (d) |
N/A 0.6 mm |
Operating Temperature Range |
N/A -40 to +110 ºC |
Capacitance Tolerance (±) at 1 Kilohertz (kHz) Frequency, 20 Degree Celsius (ºC) Temperature |
N/A 10 % |
Maximum Dissipation Factor (Tan δ) at 1 Kilohertz (kHz) Frequency and 20 Degree Celsius (ºC) Temperature |
N/A 0.1 % |
Self-Inductance |
N/A ≤ 1 Nano-Henry per mm of lead spacing and lead length |
Impulse Voltage (24 Pulses) |
N/A
C ≤ 1 µF Vp= 2.5 kVDC C > 1 µF Vp= 2.5 kV √C |
Capacitance Temperature Coefficient |
N/A ±100 ppm/ºC-200 ppm/ºC |
Construction |
N/A Metallized Polypropylene film |
Electrodes |
N/A Vacuum deposited Metal layers |
Coating |
N/A Flame retardant Solvent resistant plastic case with epoxy end fill (UL94V-0) |
Lead Terminations |
N/A Lead Free Tinned Copper Leads |
Industry Standards |
N/A Canadian Standards Association (CSA®) China Quality Certification (CQC) European Norms Electrical Certification (ENEC) Underwriters Laboratories (UL) |
Alternating Current (AC) Voltage
Alternating Current (AC) Voltage for Canadian Standards Association (CSA) |
N/A 250 V310 V |
Alternating Current (AC) Voltage for European Norms Electrical Certification (ENEC) |
N/A 305 V |
Alternating Current (AC) Voltage for China Quality Certification (CQC) |
N/A 275 V |
Alternating Current (AC) Voltage for Underwriters Laboratories (UL) |
N/A 250 V310 V |
Insulation Resistance at 20 Degree Celsius (ºC) (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volt (V) Direct Current Voltage (VDC) Applied
Terminal to Terminal Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volts (V) Direct Current (DC) Voltage Applied |
N/A 15000 MΩ |
Terminal to Case Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volts (V) Direct Current (DC) Voltage Applied |
N/A > 30000 MΩ |
Terminal to Case Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 500 Volts (V) Direct Current (DC) Voltage Applied |
N/A > 5000 MΩ |
Dielectric Strength
Terminal to Terminal Dielectric Strength |
N/A
1500 VAC or 2121 VDC applied for 60 Seconds Cut-off current: 2 A ac or 10 mAdc Current limiting resistance: 1 Ω/V |
Terminal to Case Dielectric Strength |
N/A 2050 VDC applied between the terminals and case for 60 Seconds and 20 ºC |
Life Expectancy
Note for Life Expectancy |
N/A 1000 hours at 110 ºC at 125% of rated voltage with once every hour the voltage is increased to 1000 VAC for 0.1 seconds |
Capacitance Change (Life Expectancy) |
N/A ≤ 5 % of Initially Measured Value |
Dissipation Factor Change (Life Expectancy) |
N/A ≤ 0.15 % at 1 kHz |
Insulation Resistance Change (Life Expectancy) |
N/A
≥ 100 % of initially specified value (T-T) ≥ 3000 MO (Terminal to case) |
Humidity Test
Note for Humidity Test |
N/A
500 Hours at 90 to 95% RH, 40C and no voltage applied after which the following voltage will be applied for 1 minute to each capacitor. C < 0.0068 µF 1500 VAC, C > 0.0068 µF 1075 VAC |
Capacitance Change (Humidity Test) |
N/A ≤ 5 % of Initially Measured Value |
Dissipation Factor Change (Humidity Test) |
N/A ≤ 0.15 % at 1 kHz |
Insulation Resistance Change (Humidity Test) |
N/A
≥ 50 % of initially specified value (T-T) ≥ 15000 MO (Terminal to case) |