Class x 2 EMI/RFI
Unit of Measure

Specifications

Available

N/A {0}

Manufacturer Stock

N/A {0}

Brands

N/A Cornell Dubilier

Manufacturer

N/A Cornell Dubilier

Capacitance

N/A 0.1 µF

dv/dt Rating

N/A 400 V/µs

Operating Temperature Range

N/A -40 to +110 ºC

Capacitance Tolerance (±) at 1 Kilohertz (kHz) Frequency, 20 Degree Celsius (ºC) Temperature

N/A 10 %

Frequency Range

N/A 50 Hz60 Hz

Maximum Dissipation Factor (Tan δ) at 1 Kilohertz (kHz) Frequency and 20 Degree Celsius (ºC) Temperature

N/A 1 %

Self-Inductance

N/A ≤ 1 Nano-Henry per mm of lead spacing

Impulse Voltage (24 Pulses)

N/A C < 1 uF Vp= 2.5 kVDC
C > 1 uF Vp= 2.5 kV√C

Capacitance Temperature Coefficient

N/A ±100 ppm/ºC-200 ppm/ºC

Construction

N/A Metallized Polypropylene film

Electrodes

N/A Vacuum deposited Metal layers

Coating

N/A Flame retardant Solvent resistant plastic case with epoxy end fill (UL94V-0)

Lead Terminations

N/A Tinned Copper Clad Steel Leads

Dimensions

Dimension L

N/A 18 mm

Dimension H

N/A 11 mm

Dimension T

N/A 5 mm

Dimension S

N/A 15 mm

Dimension d

N/A 0.8 mm

Alternating Current (AC) Voltage

Alternating Current (AC) Voltage for Underwriters Laboratories (UL)/Canadian Standards Association (CSA)1 N/A 250 V275 V310 V
Alternating Current (AC) Voltage for European Norms Electrical Certification (ENEC)2 N/A 250 V275 V310 V

Alternating Current (AC) Voltage for China Quality Certification (CQC)

N/A 310 V

Insulation Resistance at 20 Degree Celsius (ºC) (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volt (V) Direct Current Voltage (VDC) Applied

Terminal to Terminal Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volts (V) Direct Current (DC) Voltage Applied

N/A 15000 MΩ

Terminal to Case Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 100 Volts (V) Direct Current (DC) Voltage Applied

N/A > 30000 MΩ

Terminal to Case Insulation Resistance at 20 Degree Celsius (ºC) Temperature (<70 % Relative Humidity (RH)) for 1 Minute (min) at 500 Volts (V) Direct Current (DC) Voltage Applied

N/A > 5000 MΩ

Dielectric Strength

Terminal to Terminal Dielectric Strength

N/A 1333 VDC (4.3 x 310) VDC applied for 60 seconds
Cut-off current: 10 mAdc
Current limiting resistance: 1 Ω/V

Terminal to Case Dielectric Strength

N/A 2050 VDC (50/60 Hz) applied between the terminals and case for 60 Seconds and 20 ºC

Life Expectancy

Note for Life Expectancy

N/A 1000 hours at 110 ºC at 125% of rated voltage with once every hour the voltage is increased to 1000 VAC for 0.1 seconds

Capacitance Change (Life Expectancy)

N/A ≤ 10 % of Initially Measured Value

Dissipation Factor (Life Expectancy)

N/A ≤ 0.8 % at 1 kHz

Insulation Resistance (Life Expectancy)

N/A ≥ 50 % of initially specified value (T-T)

Humidity Test

Note for Humidity Test

N/A 56 days at 90 to 95% RH, 40C

Capacitance Change (Humidity Test)

N/A ≤ 10 % of Initially Measured Value

Dissipation Factor (Humidity Test)

N/A ≤ 0.8 % at 1 kHz

Insulation Resistance (Humidity Test)

N/A ≥ 50 % of initially specified value (T-T)

Features

Features

N/A
  • Small Size
  • Safety Agency Approved
  • Metalized Polypropylene

Applications

Applications

N/A
  • EMI filters
  • Across the line
  • 1 For T> +85 ºC , The voltage must be decreased by 1.25 % per ºC
  • 2 For T> +85 ºC , The voltage (DC/AC) must be decreased by (1.5/2.25) % per ºC