+125 ?C Highest capacitance & Voltage
Unit of Measure
Specifications
|
Dimensions
|
Load Life
|
Humidity Test
|
Surge Voltage Test
|
Ripple Current Multipliers
|
Features
|
Applications
Specifications
Available |
N/A {0} |
Manufacturer Stock |
N/A {0} |
Brands |
N/A Cornell Dubilier |
Manufacturer |
N/A Cornell Dubilier |
Series |
N/A AVG |
Working Direct Current (DC) Voltage |
N/A 63 V |
Capacitance |
N/A 180 µF |
Maximum Equivalent Series Resistance (ESR) at 120 Hertz (Hz) Frequency, +20 Degree Celsius (ºC) Temperature |
N/A 1.1052 Ω28 mΩ |
Leakage Current |
N/A 2268 µA |
Maximum Root Mean Square (RMS) Ripple Current at 100 Kilohertz (Hz) Frequency, +105 Degree Celsius (ºC) Temperature |
N/A 2550 mA |
Operating Temperature Range |
N/A -55 to +125 ºC |
Capacitance Tolerance (±) at 120 Hertz (Hz) Frequency, 20 Degree Celsius (ºC) Temperature |
N/A 20 % |
Direct Current Surge Voltage (SVDC) |
N/A 1.15 V |
Maximum Dissipation Factor (Tan δ) at 120 Hertz (Hz) Frequency, 20 Degree Celsius (ºC) Temperature |
N/A 12 % |
Low Temperature Stability Impedance Ratio (120 Hertz (Hz)) at -55 to +20 Degree Celsius (ºC) Temperature |
N/A ≤ 1.25 |
Failure Rate |
N/A 0.5 %/1000 hours Maximum (60 % confidence level at 125 ºC) |
Load Life
Load Life |
N/A 1500 Hours at 125 ºC with rated WVDC applied |
Capacitance Change (Load Life) |
N/A ≤ 30 % of Initially Measured Value |
Dissipation Factor (Load Life) |
N/A ≤ 300 % of maximum specified value |
Equivalent Series Resistance (ESR) (Load Life) |
N/A ≤ 300 % of maximum specified value |
Leakage Current (Load Life) |
N/A ≤ 100 % of maximum specified value |
Humidity Test
Note for Humidity Test |
N/A 1000 hours at 20 ºC with rated voltage applied at 90-95 % R.H. |
Capacitance Change (Humidity Test) |
N/A ≤ 20 % of Initially Measured Value |
Dissipation Factor (Humidity Test) |
N/A ≤ 150 % of maximum specified value |
Equivalent Series Resistance (ESR) (Humidity Test) |
N/A ≤ 150 % of maximum specified value |
Leakage Current (Humidity Test) |
N/A ≤ 100 % of maximum specified value |
Surge Voltage Test
Note for Surge Voltage Test |
N/A 1000 cycles at 125 ºC with rated surge voltage applied for 30 seconds through a 1 kΩ resistor and discharged for 5 minutes and 30 seconds |
Capacitance Change (Surge Voltage Test) |
N/A ≤ 20 % of initially measured value |
Dissipation Factor (Surge Voltage Test) |
N/A ≤ 150 % of maximum specified value |
Equivalent Series Resistance (ESR) (Surge Voltage Test) |
N/A ≤ 150 % of maximum specified value |
Leakage Current (Surge Voltage Test) |
N/A ≤ 100 % of maximum specified value |
Ripple Current Multipliers
Ripple Current Multipliers at 120 Hertz (Hz) Frequency |
N/A 0.05 |
Ripple Current Multipliers at 1 Kilohertz (kHz) Frequency |
N/A 0.3 |
Ripple Current Multipliers at 10 Kilohertz (kHz) Frequency |
N/A 0.7 |
Ripple Current Multipliers at 100 to 300 Kilohertz (kHz) Frequency |
N/A 1.0 |
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok